Skip to main content
Schneider Electric EZCV250N44125 — Molded Case Circuit Breakers (MCCB)

Schneider Electric EZCV250N44125 EasyPact MCCB, 125A 4P 20kA

MPNEZCV250N44125
Obsolete

Schneider Electric EasyPact EZCV250N, EZCV250N44125, 4-pole MCCB, 125 A at 40 °C, 20 kA Icu at 440 V AC, thermal-magnetic TM-D trip unit, earth-leakage protection, IP20, IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

EZCV250N44125 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZCV250N44125 — Mechanical
ParameterValue
Height165 mm
Width140 mm
Depth68 mm
EZCV250N44125 — Electrical
ParameterValue
[In] rated current125 A at 40 °C
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage440 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to IEC 60947-2
EZCV250N44125 — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZCV250N
StandardsGB/T 14048.2 EN/IEC 60947-2 JIS C8201-2-2 EN/IEC 60947-1

Product details

The Schneider Electric EZCV250N44125 is an EasyPact EZCV250N moulded-case circuit breaker (MCCB) rated 125 A at 40 °C, with a 4-pole configuration (4P) for three-phase plus neutral distribution. It uses a thermal-magnetic TM-D trip unit and includes integral earth-leakage protection, overload protection, and short-circuit protection — all in one package. The breaking capacity is 20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2, with higher ratings at lower voltages: 25 kA at 380–415 V and 85 kA at 220–240 V.

Fixed backplate mounting — no DIN-rail clip. The 140 mm width × 165 mm height × 68 mm depth footprint fits standard distribution panel cutouts. Connection pitch is 35 mm, matching common MCCB terminal spacing. IP20 finger-safe enclosure means it's protected against accidental contact but not washdown — panel interior only.

The TM-D trip unit gives a fixed thermal curve for overloads and a magnetic pickup for short-circuits; it's not adjustable, so coordination studies need to respect the fixed curve. Earth-leakage protection is built in — no separate RCCB or RCBO needed for that function. Pollution degree 3 allows installation in environments with conductive pollution (condensation, light dust).

Frequently asked questions

What is the breaking capacity of EZCV250N44125?

20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 380–415 V it is 25 kA, and at 220–240 V it is 85 kA.

What standards does EZCV250N44125 comply with?

It complies with GB/T 14048.2, EN/IEC 60947-2, JIS C8201-2-2, and EN/IEC 60947-1.

Where can I buy EZCV250N44125?

It is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN