Skip to main content
Schneider Electric EZCV250N44160 — Molded Case Circuit Breakers (MCCB)

Schneider Electric EZCV250N44160 EasyPact EZCV250N, 160 A, 2

MPNEZCV250N44160
Obsolete

Schneider Electric EasyPact EZCV250N, MCCB, 160 A, 20 kA Icu at 440 V AC, 4 poles, TM-D thermal-magnetic trip unit, with earth-leakage protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

EZCV250N44160 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZCV250N44160 — Mechanical
ParameterValue
Height165 mm
Width140 mm
Depth68 mm
EZCV250N44160 — Electrical
ParameterValue
[In] rated current160 A at 40 °C
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage440 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to IEC 60947-2
EZCV250N44160 — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZCV250N
StandardsGB/T 14048.2 EN/IEC 60947-1 JIS C8201-2-2 EN/IEC 60947-2

Product details

160 A MCCB with integrated earth-leakage protection

The Schneider Electric EZCV250N44160 is a 4-pole EasyPact EZCV250N moulded-case circuit breaker rated at 160 A at 40 °C, fitted with a TM-D thermal-magnetic trip unit and built-in earth-leakage protection. It delivers a breaking capacity of 20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2, with higher ratings at lower voltages — 25 kA at 380–415 V and 85 kA at 220–240 V. This makes it a solid choice for distribution panels where fault levels stay under 20 kA at the service voltage, and the earth-leakage module saves a separate RCCB slot in the enclosure.

The EZCV250N44160 ships as a complete breaker with the TM-D trip unit pre-installed and earth-leakage protection integrated. Mounting is fixed backplate with a 35 mm connection pitch between poles. The toggle handle gives positive contact indication — you see the contact state, not just the handle position. IP20 finger-safe terminals and IK07 impact resistance cover panel-side handling. No holes in the box: the kit includes the breaker, trip unit, and earth-leakage module as one assembly.

Compliance and standards coverage

The breaker carries approvals to GB/T 14048.2, EN/IEC 60947-1, JIS C8201-2-2, and EN/IEC 60947-2.

Frequently asked questions

Where can I buy EZCV250N44160 and how do I get a price?

The EZCV250N44160 is available to order through independent industrial-automation distributors. Submit an RFQ for current pricing and availability — both are confirmed at quote time.

What is EZCV250N44160's breaking capacity at 440 V?

The EZCV250N44160 delivers 20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 380–415 V it reaches 25 kA, and at 220–240 V it reaches 85 kA.

What compliance documentation does this brand provide for EZCV250N44160?

The EZCV250N44160 is certified to GB/T 14048.2, EN/IEC 60947-1, JIS C8201-2-2, and EN/IEC 60947-2. It carries IP20 finger-safe protection and IK07 impact resistance. The manufacturer provides IEC 60947-2 declaration of conformity and test reports on request.