Skip to main content
Schneider Electric EZCV250N44175 — Molded Case Circuit Breakers (MCCB)

Schneider Electric EZCV250N44175 EasyPact EZCV250N, 175 A, 4

MPNEZCV250N44175
Obsolete

Schneider Electric EasyPact EZCV250N, MCCB, 175 A, 4P, 20 kA Icu at 440 V AC, thermal-magnetic TM-D trip unit, earth-leakage protection, IP20, backplate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

EZCV250N44175 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZCV250N44175 — Mechanical
ParameterValue
Height165 mm
Width140 mm
Depth68 mm
EZCV250N44175 — Electrical
ParameterValue
[In] rated current175 A at 40 °C
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage440 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to IEC 60947-2
EZCV250N44175 — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZCV250N
StandardsGB/T 14048.2 EN/IEC 60947-2 EN/IEC 60947-1 JIS C8201-2-2

Product details

The Schneider Electric EZCV250N44175 is a 4-pole EasyPact EZCV250N moulded-case circuit breaker (MCCB) rated 175 A at 40 °C with a thermal-magnetic TM-D trip unit. The 20 kA Icu at 440 V AC (50/60 Hz) per IEC 60947-2 is the ultimate breaking capacity — the breaker can safely interrupt a fault at that level once and remain functional.

Protection and deployment context

This MCCB combines short-circuit, overload, and earth-leakage protection in one package — the earth-leakage element saves a separate RCCB in the panel. The TM-D trip unit is thermal-magnetic: the thermal bimetal handles overloads (inverse-time curve), and the magnetic coil trips instantaneously on short-circuit. The IP20 finger-safe enclosure and IK07 impact resistance suit it for backplate mounting inside a distribution cabinet, not for outdoor or washdown locations.

Frequently asked questions

What is the breaking capacity of EZCV250N44175?

The EZCV250N44175 has a breaking capacity of 20 kA Icu at 440 V AC, 85 kA Icu at 220–240 V AC, and 25 kA Icu at 380–415 V AC, all per IEC 60947-2.

What protection functions does this circuit breaker include?

It provides short-circuit protection, overload protection, and earth-leakage protection via a thermal-magnetic TM-D trip unit.

Where can I buy EZCV250N44175 and how is it quoted?

The EZCV250N44175 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
EZCV250N44175