Skip to main content
Schneider Electric EZS400F3400 — Circuit Breaker Accessories

Schneider Electric EZS400F3400 EasyPact EZS Circuit Breaker,

MPNEZS400F3400
Obsolete

Schneider Electric EasyPact EZS series, EZS400F3400, 3-pole molded case circuit breaker, 400 A rated current, TM-D thermal-magnetic trip unit, 40 kA Icu at 240 V AC, fixed backplate mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZS400F3400 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact EZS
EZS400F3400 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]400 A at 40 °C
Rated operational voltage [Ue]440 V AC 50/60 Hz conforming to EN/IEC 60947-2 400 V AC 50/60 Hz conforming to GB 14048.2
Rated insulation voltage [Ui]690 V conforming to EN/IEC 60947-2
Rated impulse withstand voltage [Uimp]8 kV conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZS400F3400 — Protection & Performance
ParameterValue
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to GB 14048.2 35 kA Icu at 380/400 V AC 50/60 Hz conforming to GB 14048.2
Rated service breaking capacity [Ics]40 kA at 220/230 V AC 50/60 Hz conforming to GB 14048.2 35 kA at 380/400 V AC 50/60 Hz conforming to GB 14048.2 40 kA at 200/240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 23 kA at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity codeF
Trip unit technologyThermal-magnetic
Trip unit rating400 A at 40 °C
Trip unit nameTM-D
Protection typeShort-circuit protection (magnetic) Overload protection (thermal)
Suitability for isolationYes
Utilisation categoryCategory A
Mechanical durability15000 cycles conforming to EN/IEC 60947-2 10000 cycles conforming to GB 14048.2
Electrical durability12000 cycles 415 V In/2 conforming to EN/IEC 60947-2 8000 cycles 400 V In conforming to GB 14048.2
EZS400F3400 — Mechanical
ParameterValue
Connection pitch45 mm
Downside connectionFront
Upside connectionFront
Device short nameEZS400F
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width150 mm
Height257 mm
Depth108 mm
EZS400F3400 — Environmental
ParameterValue
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60947-1
Operating ambient air temperature-35...70 °C
Storage ambient air temperature-50...85 °C
EZS400F3400 — Approvals
ParameterValue
StandardsEN 60947-2 IEC 60947-2

Product details

What this 400 A MCCB does on a distribution board

That fixed trip gives you short-circuit (magnetic) and overload (thermal) protection in one package — no field-adjustable long-time pickup, so it's a straight swap-in for a 400 A distribution feeder or large motor branch circuit where you don't need tweaking. Breaking capacity hits 40 kA Icu at 220/240 V AC and 36 kA Icu at 380/400 V AC (50/60 Hz) per EN/IEC 60947-2. The 36 kA at 400 V covers typical transformer-fed fault levels without cascading upstream.

Fixed backplate mount with a 45 mm connection pitch. Neutral position is left, so plan your bus layout accordingly. Dimensions: 257 mm high, 150 mm wide, 108 mm deep. IP40 enclosure (finger-safe, no water protection) and IK07 impact resistance — fine inside a locked panel, not for outdoor or washdown locations.

The TM-D trip holds a fixed 1 In long-time pickup, so it carries 400 A indefinitely and trips on overload above that. Electrical endurance: 12000 cycles at 415 V at In/2 per EN/IEC 60947-2. Mechanical durability is 15000 cycles. That's typical for a distribution breaker — not rated for frequent switching like a contactor, but fine for infrequent on/load-off operation. Category A (no intentional short-time delay) means it's not designed for selective coordination downstream — use it as a main or feeder breaker where you rely on upstream devices for backup protection.

Frequently asked questions

What are the key ratings of the EZS400F3400?

400 A rated current at 40 °C, 40 kA Icu at 240 V AC, 36 kA Icu at 400 V AC, 3-pole, thermal-magnetic TM-D trip unit, fixed backplate mount with front-front connections.

What compliance standards does the EZS400F3400 meet?

It complies with EN 60947-2 and IEC 60947-2 for circuit breakers, and IEC 60947-1 for pollution degree 3. Suitable for isolation per the standard.

MPN