Skip to main content
Schneider Electric G12E3F50 — Miniature Circuit Breakers (MCB)

Schneider Electric G12E3F50 GoPact MCCB 125, 50 A, 15 kA, 3P

MPNG12E3F50
Active

Schneider Electric GoPact MCCB 125, G12E3F50, 3P, 50 A thermal-magnetic (TM-D), 15 kA at 415 V AC, IP20, fixed mount.

$81.92Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12E3F50 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12E3F50 — Ratings
ParameterValue
Rated current (In)50 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12E3F50 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12E3F50 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12E3F50 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12E3F50 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12E3F50 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity15 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12E3F50 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range1 x In
Trip unit protection functionsLI

Product details

The G12E3F50 is a 3-pole GoPact MCCB 125 rated 50 A at 40 °C with a 15 kA breaking capacity at 380/415 V AC. For a 50 A feeder, the magnetic pickup is fixed and non-adjustable on this TM-D variant.

Isolation suitability is confirmed per EN/IEC 60947-2 — the breaker provides visible isolation when open, which matters for lockout/tagout procedures during panel maintenance.

Integration notes

Dimensions: 130 mm height, 75 mm width, 60 mm depth. The 75 mm width per 3-pole unit is standard for this frame size — check gland-plate fill factor if retrofitting into a crowded enclosure. Power dissipation is 18.7 W per pole, so at full load the breaker dumps about 56 W into the panel. Account for that in thermal derating if the enclosure is sealed or tightly packed. Ambient operating range is -20 to 55 °C; storage range is -35 to 85 °C. Altitude derating kicks in above 2000 m: no derating up to 2000 m, then apply the standard IEC derating factors up to 5000 m. Electrical durability is 8000 cycles at rated current; mechanical durability is 30000 cycles. For frequent switching applications (e.g., capacitor bank or motor starting), those cycle counts set the replacement interval.

Frequently asked questions

Where can I buy G12E3F50 and what is the lead time?

The G12E3F50 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest lead time.

What is the breaking capacity of G12E3F50?

The G12E3F50 has a 15 kA interrupting rating at 380/415 V AC, performance level E. This means it can safely clear a fault current up to 15 kA at that voltage level.

What compliance standards does G12E3F50 meet?

The G12E3F50 complies with EN/IEC 60947-1, EN/IEC 60947-2, and EN/IEC 60947-2 Annex H. It is also certified for isolation use per EN/IEC 60947-2.

MPN
G12E3F50