Schneider Electric G12F3A80 — Miniature Circuit Breakers (MCB)

Schneider Electric G12F3A80 GoPact MCCB 125, 80 A, 30 kA, 3P

MPNG12F3A80
Active

Schneider Electric GoPact MCCB 125, G12F3A80, 3P, 80 A TM-D trip unit, 30 kA at 415 V AC, IP20, fixed backplate mount.

$87.56Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12F3A80 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12F3A80 — Ratings
ParameterValue
Rated current (In)80 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12F3A80 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12F3A80 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12F3A80 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12F3A80 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12F3A80 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity30 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12F3A80 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.8...1 x In
Trip unit protection functionsLI

Product details

Mounting is fixed to a backplate via screw terminals, with front-facing connections on both line and load sides — a clean layout for panel builders who want all terminations accessible from the front. The 75 mm width and 60 mm depth fit standard distribution board cutouts; the 25 mm connection pitch matches common busbar and cable lug spacing.

Pollution degree 3 (IEC 60664-1) and overvoltage category III suit fixed installations with mains transients. The 440 V insulation voltage provides headroom above the 415 V operational voltage.

Integration and compliance notes

The IP20 finger-safe terminals protect against accidental contact during maintenance, but the breaker is not sealed against dust or moisture; install in a clean, dry enclosure. At altitudes above 2000 m, derate per the manufacturer's curve up to 5000 m. Power dissipation is 18.7 W per pole at rated current — account for that in the panel's thermal budget to avoid nuisance tripping from ambient heat buildup.