Schneider Electric G12T3A40 GoPact MCCB 125, 40 A, 3P, 10 kA

MPNG12T3A40
Active

Schneider Electric GoPact MCCB 125, G12T3A40, 3-pole, 40 A thermal-magnetic trip unit (TM-D), 10 kA breaking capacity at 415 V AC, fixed mount, screw terminals.

$85.64Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12T3A40 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12T3A40 — Ratings
ParameterValue
Rated current (In)40 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12T3A40 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12T3A40 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12T3A40 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12T3A40 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12T3A40 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity10 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity10 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12T3A40 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.8...1 x In
Trip unit protection functionsLI

Product details

It is rated for distribution duty (Category A) and carries a 10 kA breaking capacity at 415 V AC, 50/60 Hz, per EN/IEC 60947-2.

Mounting and integration notes

Mounts fixed to a backplate — not DIN-rail snap-on — so plan for screw-terminal connection with a 25 mm pole pitch. Accepts horizontal or vertical orientation, flat on the back. Front terminals on both line and load sides simplify busbar or cable routing in a standard distribution panel.

Durability and thermal budget

Mechanical durability is rated at 30,000 cycles; electrical durability at 8,000 cycles at rated current and 415 V. That is typical for a distribution MCCB — not intended for frequent switching like a contactor, but reliable for occasional isolation and fault protection over the panel's service life. Power dissipation per pole is 18.7 W at rated current, so total 3-pole dissipation is about 56 W — account for that in enclosure thermal calculations. Altitude derating applies above 2000 m — no derating needed below that.