Skip to main content
Schneider Electric G12T3A80 — Miniature Circuit Breakers (MCB)

G12T3A80 GoPact MCCB 125, 80 A, 10 kA, 3P Thermal-Magnetic

MPNG12T3A80
Active

Schneider Electric GoPact MCCB 125 series, G12T3A80, 3-pole 80 A thermal-magnetic circuit breaker, 10 kA breaking capacity at 415 V AC, IP20 finger protection.

$87.56Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

G12T3A80 — Identification
ParameterValue
Product nameGoPact MCCB 125
Product range (series)GoPact MCCB
Product/component typeCircuit breaker
Device applicationDistribution
G12T3A80 — Ratings
ParameterValue
Rated current (In)80 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)440 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
G12T3A80 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)8000 cycles at 415 V In
Mechanical durability (cycles)30000 cycles
G12T3A80 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
G12T3A80 — Environmental
ParameterValue
Operating ambient temperature-20...55 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
G12T3A80 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
G12T3A80 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity10 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity10 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
G12T3A80 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.8...1 x In
Trip unit protection functionsLI

Product details

The G12T3A80 is a GoPact MCCB 125 fixed-mount 3-pole circuit breaker with an 80 A TM-D thermal-magnetic trip unit. The thermal-magnetic trip gives you L (thermal overload) and I (magnetic short-circuit) protection — no ground-fault or long-time electronic adjustment, so it's a straight replacement for a thermal-magnetic MCCB in a distribution application. Rated operational voltage is 415 V AC 50/60 Hz, insulation voltage 440 V AC, both per EN/IEC 60947-2. Mount it horizontally or vertically flat on the backplate; screw terminals front-connected top and bottom with a 25 mm connection pitch.

It's a current-production catalog item in the GoPact MCCB 125 range.

Fixed-mount on a backplate with screw terminals — no DIN-rail adapter on this frame. Ambient operating range is -20 to 55 °C; storage from -35 to 85 °C. Operating altitude to 2000 m without derating, 2000-5000 m with derating.

Durability and dissipation

Mechanical durability is 30,000 cycles; electrical durability 8,000 cycles at 415 V at rated current. Utilisation category A means it's not intended for frequent motor switching under load; it's a distribution breaker, not a motor-starter combination.

Frequently asked questions

What is the breaking capacity of G12T3A80?

The G12T3A80 has a 10 kA breaking capacity at 380/415 V AC — the T performance level. That's the maximum fault current it can safely interrupt at that voltage.

What standards does G12T3A80 comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-2, and EN/IEC 60947-2 Annex H. It is suitable for isolation per those standards.

Where can I buy G12T3A80 and how is it quoted?

The G12T3A80 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
G12T3A80