Specifications

GV2DM102F7 — Identification
ParameterValue
Product range (series)TeSys Deca
Product/component typeMotor starter
GV2DM102F7 — Ratings
ParameterValue
Poles configuration3P
Utilisation categoryAC-3
GV2DM102F7 — Mechanical
ParameterValue
Width45 mm
Height176.4 mm
Depth99.6 mm
GV2DM102F7 — Other specifications
ParameterValue
Motor power0.06 kW at 400/415 V AC 50/60 Hz 0.06 kW at 440 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2DM
Device composition1 combination block GV2AF3 1 3-pole contactor 1 motor circuit breaker type GV2ME
Motor starter typeNon reversing
Breaking capacityIq 50 kA at 400/415 V conforming to IEC 60947-4-1 Iq 50 kA at 440 V conforming to IEC 60947-4-1 Iq 50 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current2.4 A
Thermal protection adjustment range0.16...0.25 A

Product details

The GV2DM102F7 is a non-reversing DOL combination starter from the TeSys Deca family, integrating a GV2ME motor circuit breaker and a 3-pole contactor in one block with a GV2AF3 auxiliary contact block. Its thermal protection adjustment range of 0.16…0.25 A makes it suited for very small motor loads — think fractional-horsepower pumps, small fans, or conveyor drives below 0.06 kW at 400/415 V AC. Rated breaking capacity hits 50 kA at 400/415 V (IEC 60947-4-1), so it can clear a bolted fault on a 50 kA available fault-current bus without upstream coordination worries — Type 1 coordination means the starter may need replacement after a fault, but the downstream motor stays protected. The magnetic tripping threshold is fixed at 2.4 A, which triggers instantaneously on short-circuit; the thermal bimetallic element handles the 0.16…0.25 A overload band. That narrow window means this part is not a general-purpose breaker — it is sized specifically for the motor's full-load current.

The 0.06 kW motor power rating at 400/415 V AC (50/60 Hz) and 0.06 kW at 440 V AC is the headline selection parameter — this starter is for sub-0.1 kW motors only. The 110 V AC coil voltage means the control circuit must supply 110 V AC; verify your panel's control transformer voltage before specifying. Dimensions (176.4 mm height, 45 mm width, 99.6 mm depth) fit a standard DIN-rail footprint. The 45 mm width is typical for a 3-pole motor starter in the TeSys Deca range.

Frequently asked questions

Where can I buy GV2DM102F7 and how do I get a price?

The GV2DM102F7 is sourced through independent distribution channels — new-old-stock or verified surplus. Submit an RFQ; availability and current pricing are confirmed at quote time. No stock count or price figure is published here.

What is the thermal protection adjustment range of GV2DM102F7?

The thermal protection adjustment range is 0.16…0.25 A, set via the bimetallic overload relay integrated into the motor circuit breaker section.

What breaking capacity does GV2DM102F7 offer?

Rated breaking capacity is 50 kA at 400/415 V AC and at 440 V AC, per IEC 60947-4-1. This covers most industrial distribution panels with high available fault current.