Schneider Electric GV2DM114V7 — Miniature Circuit Breakers (MCB)

Schneider Electric GV2DM114V7 TeSys Deca Motor Starter, 6-10

MPNGV2DM114V7
Active

Schneider Electric TeSys Deca GV2DM114V7, DOL combination motor starter, 6-10 A thermal protection, 3 kW at 400 V AC, 3-pole non-reversing.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2DM114V7 — Identification
ParameterValue
Product range (series)TeSys Deca
Product/component typeMotor starter
GV2DM114V7 — Ratings
ParameterValue
Poles configuration3P
Utilisation categoryAC-3
GV2DM114V7 — Mechanical
ParameterValue
Width45 mm
Height176.4 mm
Depth99.6 mm
GV2DM114V7 — Other specifications
ParameterValue
Motor power3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz
Coordination typeType 1
Device short nameGV2DM
Device composition1 motor circuit breaker type GV2ME 1 3-pole contactor 1 combination block GV2AF3
Motor starter typeNon reversing
Breaking capacityIq 50 kA at 400/415 V conforming to IEC 60947-4-1 Iq 15 kA at 440 V conforming to IEC 60947-4-1 Iq 6 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current138 A
Thermal protection adjustment range6...10 A

Product details

The GV2DM114V7 is a DOL combination motor starter from the TeSys Deca range, packing a GV2ME motor circuit breaker, a 3-pole contactor, and a GV2AF3 combination block into one 45 mm wide package. The thermal protection adjustment range of 6...10 A sets the overload relay trip point, and the magnetic trip is fixed at 138 A for short-circuit protection. Rated breaking capacity hits 50 kA at 400/415 V per IEC 60947-4-1, so it handles fault currents on a typical 400 V line without upstream coordination headaches.

AC-3 utilisation category means this starter is built for squirrel-cage motor switching — making and breaking stalled-rotor currents during start/stop cycles. The motor power table lists 3 kW at 400/415 V and 4 kW at 440 V, so it covers standard 4-pole induction motors in that power band. Type 1 coordination means the contactor and overload relay may need replacement after a short-circuit fault, but the starter itself stays intact — no downstream damage.

Frequently asked questions

What is the closest alternative to GV2DM114V7 in the TeSys Deca family?

The GV2DM114V7 is a specific combination starter with a 6-10 A thermal range. Within the same TeSys Deca family, a unit with a different thermal range (e.g., 10-14 A) or a different contactor coil voltage would be the closest functional alternative, but no pin-compatible drop-in exists — the breaker and contactor are integrated as a single assembly.

How do I get current pricing and availability for GV2DM114V7?

The part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.