Schneider Electric GV2LC0206 — Miniature Circuit Breakers (MCB)

TeSys GV2LC0206 Enclosed DOL Starter, 1.6 A, 100 kA

MPNGV2LC0206
Obsolete

Schneider Electric TeSys GV2LC, enclosed DOL starter, 1.6 A thermal protection, 100 kA breaking capacity at 400 V, IP54, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2LC0206 — Identification
ParameterValue
Product range (series)TeSys
Product/component typeEnclosed DOL starter
GV2LC0206 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity100 kA Icu at 220...230 V conforming to IEC 60947-2 100 kA Icu at 400...415 V conforming to IEC 60947-2 100 kA Icu at 440 V conforming to IEC 60947-2 100 kA Icu at 500 V conforming to IEC 60947-2
Rated operational voltage (Ue)690 V
GV2LC0206 — Protection
ParameterValue
Trip unit technologyMagnetic
Magnetic tripping limit13 x In +/- 20 %
GV2LC0206 — Mechanical
ParameterValue
Control typeRotary handle black
Width88 mm
Height166 mm
Depth173 mm
GV2LC0206 — Environmental
ParameterValue
IP degree of protectionIP54 conforming to IEC 60529
GV2LC0206 — Approvals
ParameterValue
StandardsEN 60947 IEC 60439-1 VDE 0660-102 IEC 60947-4

Product details

The Schneider Electric TeSys GV2LC0206 is an enclosed direct-on-line (DOL) motor starter with a built-in circuit breaker, rated for a thermal protection adjustment range of 1.6 A. It is a non-reversing, 3-pole unit using magnetic trip technology, with a magnetic tripping limit of 13 x In ±20%. The enclosure is polycarbonate with an IP54 rating per IEC 60529, making it suitable for environments where dust and water splash are present, such as light industrial or washdown areas. Breaking capacity is 100 kA Icu at 220–230 V, 400–415 V, 440 V, and 500 V per IEC 60947-2. Rated operational voltage is 690 V. Cable entry accommodates 2 x 25 mm² ISO at top and bottom, and 2 x 20 mm² ISO at top and bottom, giving flexibility for panel gland-plate layout. The rotary handle (black) can be locked in the OFF position with 1 to 3 padlocks (Ø 8 mm) for lockout/tagout procedures.

Integration notes

Dimensions are 166 mm height, 88 mm width, and 173 mm depth. The IP54 polycarbonate enclosure is self-contained — no additional panel cutout is needed; it mounts directly to a machine frame or wall via the enclosure's integral fixing points. Cable entry is via ISO metric knockouts, so plan your gland selection accordingly (2 x 25 mm² top/bottom, 2 x 20 mm² top/bottom). The rotary handle protrudes from the enclosure front; ensure clearance for the handle swing and for padlock application in the OFF position. The unit is a combined circuit breaker and starter in one package — no separate overload relay is needed, which simplifies wiring but means the thermal setting (1.6 A) is fixed by the unit's adjustment range. If your motor FLA is outside that range, this unit will not provide proper overload protection.

Frequently asked questions

What is the breaking capacity of the GV2LC0206?

It has a breaking capacity of 100 kA Icu at 220–230 V, 400–415 V, 440 V, and 500 V, per IEC 60947-2. This high rating means it can handle severe fault currents without upstream devices needing to intervene.

What is the thermal protection setting range?

The thermal protection adjustment range is 1.6 A. This is a fixed setting for this unit — it protects a motor with a full-load current up to that value.

What standards does the GV2LC0206 comply with?

It complies with EN 60947, IEC 60439-1, VDE 0660-102, and IEC 60947-4. These cover motor starter and distribution applications.

MPN
GV2LC0206