Skip to main content
Schneider Electric GV2LC0208 — Molded Case Circuit Breakers (MCCB)

TeSys GV2LC0208 Enclosed DOL Starter, 4 A, IP54

MPNGV2LC0208
Active

TeSys GV2-LC enclosed DOL starter, GV2LC0208, 4 A thermal protection, 100 kA breaking capacity, IP54 polycarbonate enclosure.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2LC0208 — Identification
ParameterValue
Product / component typeEnclosed DOL starter
GV2LC0208 — Mechanical
ParameterValue
Height166 mm
Width88 mm
Depth173 mm
GV2LC0208 — Electrical
ParameterValue
Breaking capacity100 kA Icu at 220...230 V conforming to IEC 60947-2 100 kA Icu at 400...415 V conforming to IEC 60947-2 100 kA Icu at 440 V conforming to IEC 60947-2 100 kA Icu at 500 V conforming to IEC 60947-2
[Ue] rated operational voltage690 V
GV2LC0208 — Specifications
ParameterValue
Poles description3P
Trip unit technologyMagnetic
Device short nameGV2LC
StandardsIEC 60947-4 VDE 0660-102 EN 60947 IEC 60439-1

Product details

Enclosed DOL starter for motor control panels

The TeSys GV2LC0208 is an enclosed direct-on-line (DOL) starter rated for 4 A thermal protection, built into a polycarbonate enclosure with IP54 protection. It integrates a magnetic trip unit with a tripping limit of 13 x In, so it clears short-circuit faults without relying on an upstream fuse or breaker for motor branch circuits.

Panel fit and cable entry

The enclosure measures 173 mm deep by 88 mm wide by 166 mm high, sized for a standard 200 mm deep panel backplate. Cable entries are pre-cut: two 25 mm ISO knockouts at top and bottom, plus two 20 mm ISO knockouts at top and bottom — plan gland plates for these diameters before the install date. The black rotary handle protrudes from the front; padlock it in the OFF position using up to three 8 mm padlocks for lockout/tagout compliance.

It carries compliance with IEC 60947-4 (motor starters), VDE 0660-102, EN 60947, and IEC 60439-1 (low-voltage switchgear assemblies). The IP54 rating meets IEC 60529 for dust and splash protection — suitable for washdown areas or outdoor cabinets if kept out of direct hose spray.

Sourcing posture

This is a current-production TeSys GV2-LC variant. Source it against an RFQ for the project BOM; no last-time-buy or phase-out notice applies. The 4 A thermal adjustment range and 690 V rated operational voltage match the spec for small motor branch circuits up to 1.5 kW at 400 V.

Frequently asked questions

What are the key ratings for the GV2LC0208?

Thermal protection adjustment range is 4 A. Breaking capacity is 100 kA Icu at 400...415 V per IEC 60947-2. Rated operational voltage is 690 V. IP54 protection. Magnetic tripping limit is 13 x In.

What compliance documentation does the GV2LC0208 carry?

It complies with IEC 60947-4, VDE 0660-102, EN 60947, and IEC 60439-1. The IP54 rating is per IEC 60529.

What are the enclosure dimensions for panel planning?

Depth 173 mm, width 88 mm, height 166 mm. Cable entries: 2 x 25 mm ISO at top, 2 x 20 mm ISO at top, 2 x 25 mm ISO at bottom, 2 x 20 mm ISO at bottom.

MPN