Skip to main content
Schneider Electric GV2LC0210 — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2LC0210 Enclosed DOL Starter, 6.3 A, 100 k

MPNGV2LC0210
Obsolete

Schneider Electric TeSys GV2-LC enclosed DOL starter, 6.3 A thermal protection, 3-pole, non-reversing, IP54 polycarbonate enclosure.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2LC0210 — Identification
ParameterValue
Product / component typeEnclosed DOL starter
GV2LC0210 — Mechanical
ParameterValue
Height166 mm
Width88 mm
Depth173 mm
GV2LC0210 — Electrical
ParameterValue
Breaking capacity100 kA Icu at 220...230 V conforming to IEC 60947-2 100 kA Icu at 400...415 V conforming to IEC 60947-2 100 kA Icu at 440 V conforming to IEC 60947-2 100 kA Icu at 500 V conforming to IEC 60947-2
[Ue] rated operational voltage690 V
GV2LC0210 — Specifications
ParameterValue
Poles description3P
Trip unit technologyMagnetic
Device short nameGV2LC
StandardsVDE 0660-102 IEC 60947-4 IEC 60439-1 EN 60947

Product details

The Schneider TeSys GV2LC0210 is an enclosed direct-on-line (DOL) motor starter, combining a magnetic-trip circuit breaker and a rotary-handle disconnect in a single IP54 polycarbonate enclosure.

The IP54 rating means the polycarbonate enclosure is dust-protected and splash-proof, suitable for light industrial environments but not for washdown zones (that would require IP65 or higher). The 6.3 A fixed thermal setting limits this to a specific motor FLA — if your motor draws 5.5 A or 7.0 A, this is not the right thermal pickup; you would need a different GV2LC variant with the correct adjustment range.

Physical integration

The enclosure measures 173 mm deep, 88 mm wide, and 166 mm high. Cable entry is via ISO knockouts: two 20 mm at top and bottom, plus two 25 mm at top and bottom. The rotary handle accepts up to three 8 mm padlocks for lockout/tagout in the OFF position. The polycarbonate housing is non-metallic, so no additional earthing of the enclosure is required beyond the internal PE connection.

Frequently asked questions

What is the breaking capacity of this starter?

The breaking capacity is 100 kA Icu at 220...230 V, 400...415 V, 440 V, and 500 V, all conforming to IEC 60947-2. This high rating means it can be used on systems with high fault current without additional upstream protection.

What is the enclosure protection rating?

The enclosure is rated IP54 per IEC 60529, meaning it is protected against dust ingress and splashing water. It is suitable for indoor industrial environments but not for direct washdown or outdoor exposure without additional weather protection.

What thermal protection range does this starter cover?

The thermal protection adjustment range is fixed at 6.3 A. This is not an adjustable range — it is a single setting. The starter uses magnetic trip technology for short-circuit protection and a fixed thermal element for overload protection.

MPN
GV2LC0210