Skip to main content
Schneider Electric GV2LC0216R — Miniature Circuit Breakers (MCB)

Schneider TeSys GV2LC0216R Enclosed DOL Starter, 14 A, IP54

MPNGV2LC0216R
Active

Schneider Electric TeSys GV2-LC, enclosed DOL starter, GV2LC0216R, 14 A, 3-pole, IP54, rotary red handle.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

GV2LC0216R — Identification
ParameterValue
Product range (series)TeSys
Product/component typeEnclosed DOL starter
GV2LC0216R — Ratings
ParameterValue
Poles configuration3P
Breaking capacity10 kA Icu at 500 V conforming to IEC 60947-2 100 kA Icu at 220...230 V conforming to IEC 60947-2 20 kA Icu at 440 V conforming to IEC 60947-2 50 kA Icu at 400...415 V conforming to IEC 60947-2
Rated operational voltage (Ue)690 V
GV2LC0216R — Protection
ParameterValue
Trip unit technologyMagnetic
GV2LC0216R — Mechanical
ParameterValue
Control typeRotary handle red
Width88 mm
Height166 mm
Depth173 mm
GV2LC0216R — Environmental
ParameterValue
IP degree of protectionIP54 conforming to IEC 60529
GV2LC0216R — Approvals
ParameterValue
StandardsIEC 60439-1 VDE 0660-102 IEC 60947-4 EN 60947

Product details

The Schneider Electric TeSys GV2LC0216R is an enclosed direct-on-line (DOL) starter — a self-contained unit combining a circuit breaker and a contactor in a single polycarbonate enclosure, rated IP54. The 14 A thermal adjustment range sets the overload protection level for the connected motor load. This is the critical setting for matching the starter to the motor full-load current — set it at the motor nameplate FLA, not the breaker frame rating. Breaking capacity varies with supply voltage: 100 kA Icu at 220...230 V, 50 kA at 400...415 V, 20 kA at 440 V, and 10 kA at 500 V, all conforming to IEC 60947-2. At a typical 400 V industrial supply, the 50 kA rating provides substantial fault-current headroom for most panel installations.

Where it goes — deployment context

This is a wall-mount or machine-mount enclosed starter, not a DIN-rail component. The IP54 polycarbonate enclosure means it is suited for indoor industrial environments where dust and splash are present — pump stations, conveyor drives, small compressors — but not for direct washdown or outdoor exposure. Cable entry is via ISO knockouts: two at the top (20 mm and 25 mm) and two at the bottom (20 mm and 25 mm), giving flexibility for top or bottom cable entry in a panel gland plate.

The starter is designed and tested to IEC 60947-4 (the standard for contactors and motor-starters) and IEC 60947-2 (circuit-breaker standard), as well as EN 60947 and VDE 0660-102. These certifications cover the interrupting rating, coordination, and thermal performance required for motor-starting duty.

Frequently asked questions

What are the key ratings for this enclosed DOL starter?

The key ratings are: thermal protection adjustment range 14 A, breaking capacity up to 100 kA Icu at 230 V and 50 kA at 400 V (per IEC 60947-2), IP54 enclosure protection, and a 3-pole non-reversing configuration with a red rotary handle.

What compliance documentation does this part carry?

The GV2LC0216R is designed to IEC 60439-1, VDE 0660-102, IEC 60947-4, and EN 60947 standards. These cover the motor-starter and circuit-breaker performance requirements for industrial installations.

MPN