Skip to main content
Schneider Electric GV2P02TQ — Molded Case Circuit Breakers (MCCB)

Schneider Electric GV2P02TQ TeSys Deca Motor Circuit Breaker

MPNGV2P02TQ
Obsolete

Schneider Electric TeSys Deca GV2P02TQ, motor circuit breaker, 3 poles, 0.25 A rated current, thermal-magnetic, 100 kA breaking capacity.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2P02TQ — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection
GV2P02TQ — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth97 mm
GV2P02TQ — Electrical
ParameterValue
[In] rated current0.25 A
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2P02TQ — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2P
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2

Product details

Motor Circuit Breaker for 0.25 A Protection

The Schneider Electric GV2P02TQ is a TeSys Deca motor circuit breaker rated at 0.25 A, designed for protecting small motor loads up to 0.06 kW at 400/415 V AC. This high interrupting rating ensures coordination with upstream protection devices in a fault scenario, reducing the risk of cascading failures in the panel.

Standards and Compliance for Tender Submissions

Phase failure sensitivity is built in per IEC 60947-4-1, protecting the motor against single-phasing conditions.

The 45 mm width and 89 mm height fit standard DIN-rail spacing; depth is 97 mm including the rotary handle. Accepts power circuit wiring: screw clamp terminals for 2 cables of 1 to 6 mm² solid or 1.5 to 6 mm² flexible without cable end, or 1 to 4 mm² flexible with cable end. Tightening torque is 1.7 N·m.

Frequently asked questions

What are the key ratings for the GV2P02TQ?

Rated current In is 0.25 A, magnetic tripping current is 3.08 A, breaking capacity is 100 kA Icu at 400/415 V AC, and it is rated for motor protection up to 0.06 kW at 400/415 V AC.

What compliance standards does the GV2P02TQ meet?

It complies with EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, IEC/EN 60335-2-40 Annex JJ, and IEC/EN 60335-1 Clause 30.2.

How is the GV2P02TQ mounted and wired?

It mounts on a 35 mm DIN rail or directly to a panel with M4 screws. Power terminals accept 1 to 6 mm² solid or 1.5 to 6 mm² flexible wire, with a tightening torque of 1.7 N·m.

MPN
GV2P02TQ