Skip to main content
Schneider Electric GV2P03AE11 — Miniature Circuit Breakers (MCB)

Schneider Electric GV2P03AE11 TeSys GV2 Motor Circuit Breake

MPNGV2P03AE11
Obsolete

Schneider Electric TeSys GV2 motor circuit breaker, GV2P03AE11, 0.4 A, 3-pole, thermal-magnetic, 100 kA breaking capacity, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2P03AE11 — Identification
ParameterValue
Product nameTeSys GV2
Product rangeTeSys Deca
Product/component typeMotor circuit breaker
Device applicationMotor protection
GV2P03AE11 — Ratings
ParameterValue
Rated current (In)0.4 A
Poles configuration3P
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage (Ui)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz conforming to IEC 60947-2
Utilisation categoryCategory A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1
GV2P03AE11 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to IEC 60947-1
Electrical durability (cycles)100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In
Mechanical durability (cycles)100000 cycles
GV2P03AE11 — Mechanical
ParameterValue
Control typeRotary handle
Terminal connection typePower circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end
Terminal tightening torque1.7 N.m - on screw clamp terminal
Width45 mm
Height89 mm
Depth97 mm
GV2P03AE11 — Environmental
ParameterValue
Operating ambient temperature-20...60 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
GV2P03AE11 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2
GV2P03AE11 — Electrical
ParameterValue
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2

Product details

The Schneider Electric GV2P03AE11 is a 3-pole motor circuit breaker from the TeSys GV2 series, rated at 0.4 A and designed for motor protection in industrial control panels. It combines a thermal-magnetic trip unit with a rotary handle for manual control and isolation. The 0.4 A rating protects a 0.09 kW motor at 400/415 V AC, making it suited for small fractional-horsepower loads like fans, pumps, or conveyors in light-duty applications.

Breaking capacity is 100 kA Icu at 400/415 V AC, which means it can safely interrupt a fault current up to 100,000 A without failing. The thermal-magnetic trip provides overload protection via a bimetal strip and short-circuit protection via a magnetic coil. The magnetic trip threshold is fixed at 5.8 A, so it clears hard faults fast while letting motor inrush pass. Phase failure sensitivity is built in per IEC 60947-4-1, so the breaker trips if one phase drops out — critical for preventing single-phasing damage on three-phase motors.

IP20 finger-safe protection means it's suitable for enclosed panels where no washdown or dust ingress is expected. The IK04 impact rating handles incidental tool contact during commissioning. Power dissipation is 2.5 W per pole, so three poles total 7.5 W at rated current. Factor that into cabinet thermal calculations to avoid derating in a sealed enclosure.

Approvals include UL 60947-4-1, CSA C22.2 No 60947-4-1, and EN/IEC 60947-2 and 60947-4-1, so it is accepted in North American and European panels without additional certification work.

Frequently asked questions

What is the closest alternative to GV2P03AE11 in the TeSys GV2 family?

Within the TeSys GV2 range, the direct alternative is the same order code — there is no pin-compatible substitute with different ratings. For a different current rating, select the GV2Pxx variant matching your motor FLA.

What compliance documentation does Schneider provide for GV2P03AE11?

The breaker carries UL, CSA, CE, and IEC certifications per the standards listed: UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-2, and EN/IEC 60947-4-1. Fire resistance is tested to 960 °C per IEC 60695-2-11.

What is the depth of GV2P03AE11?

The depth is 97 mm, with a width of 45 mm and height of 89 mm. This fits standard DIN-rail enclosures with adequate clearance for wiring and the rotary handle.

MPN