Schneider Electric GV2P04KD09B7 — Molded Case Circuit Breakers (MCCB)

Schneider Electric GV2P04KD09B7 TeSys Motor Starter, 0.63 A,

MPNGV2P04KD09B7
Obsolete

Schneider Electric TeSys GV2P04KD09B7, direct on-line motor starter, 3-pole, 0.63 A line rated current, 24 V AC coil, 100 kA breaking capacity at 400 V AC, IP20, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2P04KD09B7 — Identification
ParameterValue
Product / component typeMotor starter
GV2P04KD09B7 — Mechanical
ParameterValue
Height3.5 in (89 mm)
Width1.8 in (45 mm)
Depth3.8 in (97 mm)
GV2P04KD09B7 — Electrical
ParameterValue
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltagePower circuit Power circuit 10 MOhm for signalling circuit
[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2
GV2P04KD09B7 — Specifications
ParameterValue
Poles description3P
StandardsVDE 0113 UL 508 EN 60204 NF C 63-650 NF C 63-120 IEC 60947-2 IEC 60947-4-1 IEC 60947-1 NF C 79-130 CSA C22.2 VDE 0660

Product details

Product Overview and Key Ratings

The GV2P04KD09B7: The breaking capacity is rated at 100 kA Icu across the full voltage range from 230/240 V up to 690 V AC per IEC 60947-2, which means this starter can safely interrupt fault currents up to 100 kA without upstream cascading — a critical parameter for coordination studies in high-fault-capacity installations. Motor power ratings span 0.12 kW at 400/415 V AC up to 0.37 kW at 690 V AC, with a motor power range covering 1.1...2 kW at 200...240 V three-phase and 2.2...3 kW at 380...440 V three-phase. The utilization categories include AC-3 for motor control and AC-1 for resistive loads, with an electrical durability of 100,000 cycles at AC-3 440 V.

Dimensions are 3.5 in (89 mm) height, 1.8 in (45 mm) width, and 3.8 in (97 mm) depth, fitting standard enclosure layouts. Screw clamp terminals accept solid conductors from 1 to 6 mm², or flexible with cable end from 1 to 4 mm², with a tightening torque of 15.05 lbf.in (1.7 N.m). The operating position is any position, and the unit is rated for continuous duty per IEC 60947-4-1.

Frequently asked questions

What compliance standards does GV2P04KD09B7 meet?

It is fully compliant with UL 508, CSA C22.2, IEC 60947-2, IEC 60947-4-1, IEC 60947-1, EN 60204, VDE 0113, VDE 0660, NF C 63-120, NF C 63-650, and NF C 79-130, covering North American and European regulatory requirements for motor starters.

What is the breaking capacity of GV2P04KD09B7?

The breaking capacity is 100 kA Icu at all rated voltages from 230/240 V through 690 V AC per IEC 60947-2, providing high fault-current interruption capability for industrial power systems.

How is GV2P04KD09B7 mounted?

It mounts on 35 mm symmetrical DIN rail via a clipped fixing, or can be panel-mounted with two M4 screws. Dimensions are 89 mm height, 45 mm width, and 97 mm depth.

MPN
GV2P04KD09B7