Skip to main content
Schneider Electric GV2P04KD09BL — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2P04KD09BL Motor Starter, 0.63 A, 100 kA

MPNGV2P04KD09BL
Obsolete

Schneider Electric TeSys GV2P04KD09BL motor starter, 3-pole, 0.63 A line rated current, 100 kA breaking capacity, 24 V AC coil, IP20, DIN-rail or panel mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2P04KD09BL — Identification
ParameterValue
Product / component typeMotor starter
GV2P04KD09BL — Mechanical
ParameterValue
Height3.5 in (89 mm)
Width1.8 in (45 mm)
Depth3.8 in (97 mm)
GV2P04KD09BL — Electrical
ParameterValue
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltagePower circuit Power circuit 10 MOhm for signalling circuit
[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2
GV2P04KD09BL — Specifications
ParameterValue
Poles description3P
StandardsVDE 0113 UL 508 EN 60204 NF C 63-650 NF C 63-120 IEC 60947-2 IEC 60947-4-1 IEC 60947-1 NF C 79-130 CSA C22.2 VDE 0660

Product details

The Schneider Electric TeSys GV2P04KD09BL is a direct on-line motor starter combining a contactor and thermal-magnetic overload relay in a single 3-pole package. It is rated for a line current of 0.63 A and provides motor protection for small horsepower loads — 0.12 kW at 400/415 V AC or 0.37 kW at 690 V AC. The breaking capacity hits 100 kA Icu across the full voltage range (230/240 V through 690 V AC), certified to IEC 60947-2. The magnetic trip is set at 8 A, which handles the inrush of a 0.63 A motor without nuisance tripping, while the thermal element protects against sustained overloads. The contactor coil is 24 V AC, standard for control transformer circuits.

The IK04 impact rating handles incidental tool contact during commissioning. Screw-clamp terminals accept 1 to 6 mm² solid or stranded wire; torque to 1.7 N·m.

Compliance documentation covers UL 508, CSA C22.2, IEC 60947-2 and -4-1, EN 60204, and VDE 0660 — the full set for North American and European panel certification. Flame retardance is V1 per UL 94; glow-wire tested to 850 °C per IEC 60695-2-1.

Frequently asked questions

What is the closest alternative to GV2P04KD09BL in the TeSys family?

Within the TeSys GV2 series, the closest pin-compatible alternative would be a unit with the same frame size and 3-pole configuration but a different thermal-magnetic trip range. The deciding factor is the motor full-load current: the GV2P04KD09BL is set for 0.63 A line current with an 8 A magnetic trip. If your motor draws a different current, select the GV2 variant whose thermal range brackets that value — the mechanical footprint and coil voltage remain identical.

What are the key ratings for this motor starter?

Line rated current is 0.63 A, breaking capacity is 100 kA Icu across all AC voltages from 230 V to 690 V, coil voltage is 24 V AC, and the magnetic trip is set at 8 A. Motor power ratings are 0.12 kW at 400/415 V and 0.37 kW at 690 V.

What compliance standards does GV2P04KD09BL meet?

It is certified to UL 508, CSA C22.2, IEC 60947-2, IEC 60947-4-1, EN 60204, VDE 0660, and NF C 63 series. Flame retardance is V1 per UL 94, and glow-wire testing passes at 850 °C.

MPN
GV2P04KD09BL