Skip to main content
Schneider Electric GV2P04TQ — Miniature Circuit Breakers (MCB)

Schneider Electric GV2P04TQ TeSys GV2 Motor Circuit Breaker,

MPNGV2P04TQ
Obsolete

Schneider Electric TeSys GV2 motor circuit breaker, GV2P04TQ, 0.63 A rated current, 3-pole, thermal-magnetic trip, 100 kA breaking capacity, AC-3 duty, IP20, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2P04TQ — Identification
ParameterValue
Product nameTeSys GV2
Product rangeTeSys Deca
Product/component typeMotor circuit breaker
Device applicationMotor protection
GV2P04TQ — Ratings
ParameterValue
Rated current (In)0.63 A
Poles configuration3P
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage (Ui)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz conforming to IEC 60947-2
Utilisation categoryCategory A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1
GV2P04TQ — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to IEC 60947-1
Electrical durability (cycles)100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In
Mechanical durability (cycles)100000 cycles
GV2P04TQ — Mechanical
ParameterValue
Control typeRotary handle
Terminal connection typePower circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end
Terminal tightening torque1.7 N.m - on screw clamp terminal
Width45 mm
Height89 mm
Depth97 mm
GV2P04TQ — Environmental
ParameterValue
Operating ambient temperature-20...60 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
GV2P04TQ — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2
GV2P04TQ — Electrical
ParameterValue
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2

Product details

It combines a thermal-magnetic trip unit — thermal overload for sustained overcurrent, magnetic trip at 9.3 A for short-circuit — with a 3-pole switching mechanism, all in a 45 mm wide package that clips onto 35 mm DIN rail or screws to a panel.

The magnetic trip at 9.3 A (roughly 15× In) clears hard shorts fast, while the thermal element handles overloads. Rated for AC-3 and AC-3e utilisation categories per IEC 60947-4-1, it's built for starting and stopping squirrel-cage motors under load. Phase failure sensitivity (per IEC 60947-4-1) means it trips if one phase drops out, preventing single-phase motor burn-up. Electrical durability is 100,000 cycles at rated current in AC-3 duty — solid for a machine tool or conveyor application.

Mounts horizontally or vertically on 35 mm DIN rail (standard for IEC enclosures) or directly to a panel with two M4 screws. IP20 finger-safe terminals suit enclosed panels; the dark grey housing is the standard TeSys Deca colour. Power connections accept up to 6 mm² solid or 4 mm² flexible with ferrule, torqued to 1.7 N·m.

Frequently asked questions

What is the breaking capacity of this motor circuit breaker?

It delivers 100 kA Icu at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC 50/60 Hz per IEC 60947-2 — a high interrupting rating that covers most industrial fault levels without needing a backup fuse.

What standards does the GV2P04TQ comply with?

It complies with EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and portions of IEC/EN 60335 for appliance applications. This covers motor protection, isolation, and global regulatory acceptance.

What is the closest alternative in the TeSys GV2 family?

Within the same TeSys GV2 series, the GV2P04TQ is the 0.63 A variant. The family shares the same 45 mm width, DIN-rail mounting, and 100 kA breaking capacity; the difference is the thermal-magnetic trip rating. A higher-current sibling like the GV2P05 (0.8 A) or GV2P06 (1 A) would be the direct swap if the motor FLA is higher.

MPN
GV2P04TQ