Skip to main content
Schneider Electric GV2P04TQ — Molded Case Circuit Breakers (MCCB)

Schneider Electric GV2P04TQ TeSys GV2 Motor Circuit Breaker,

MPNGV2P04TQ
Obsolete

Schneider Electric TeSys GV2 motor circuit breaker, GV2P04TQ, 0.63 A rated current, 3-pole, thermal-magnetic trip, 100 kA breaking capacity, AC-3 duty, IP20, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2P04TQ — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection
GV2P04TQ — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth97 mm
GV2P04TQ — Electrical
ParameterValue
[In] rated current0.63 A
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2P04TQ — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2P
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2

Product details

It combines a thermal-magnetic trip unit — thermal overload for sustained overcurrent, magnetic trip at 9.3 A for short-circuit — with a 3-pole switching mechanism, all in a 45 mm wide package that clips onto 35 mm DIN rail or screws to a panel.

The magnetic trip at 9.3 A (roughly 15× In) clears hard shorts fast, while the thermal element handles overloads. Rated for AC-3 and AC-3e utilisation categories per IEC 60947-4-1, it's built for starting and stopping squirrel-cage motors under load. Phase failure sensitivity (per IEC 60947-4-1) means it trips if one phase drops out, preventing single-phase motor burn-up. Electrical durability is 100,000 cycles at rated current in AC-3 duty — solid for a machine tool or conveyor application.

Mounts horizontally or vertically on 35 mm DIN rail (standard for IEC enclosures) or directly to a panel with two M4 screws. IP20 finger-safe terminals suit enclosed panels; the dark grey housing is the standard TeSys Deca colour. Power connections accept up to 6 mm² solid or 4 mm² flexible with ferrule, torqued to 1.7 N·m.

Frequently asked questions

What is the breaking capacity of this motor circuit breaker?

It delivers 100 kA Icu at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC 50/60 Hz per IEC 60947-2 — a high interrupting rating that covers most industrial fault levels without needing a backup fuse.

What standards does the GV2P04TQ comply with?

It complies with EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and portions of IEC/EN 60335 for appliance applications. This covers motor protection, isolation, and global regulatory acceptance.

What is the closest alternative in the TeSys GV2 family?

Within the same TeSys GV2 series, the GV2P04TQ is the 0.63 A variant. The family shares the same 45 mm width, DIN-rail mounting, and 100 kA breaking capacity; the difference is the thermal-magnetic trip rating. A higher-current sibling like the GV2P05 (0.8 A) or GV2P06 (1 A) would be the direct swap if the motor FLA is higher.

MPN
GV2P04TQ