Skip to main content
Schneider Electric GV2P05KD09G7 — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2P05KD09G7 Motor Starter, 1 A, 100 kA

MPNGV2P05KD09G7
Obsolete

Schneider Electric TeSys GV2P05KD09G7 manual motor starter, 3-pole, 1 A rated current, 100 kA breaking capacity at 400 V AC, 0.25 kW at 400 V, IP20, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2P05KD09G7 — Identification
ParameterValue
Product / component typeMotor starter
GV2P05KD09G7 — Mechanical
ParameterValue
Height3.5 in (89 mm)
Width1.8 in (45 mm)
Depth3.8 in (97 mm)
GV2P05KD09G7 — Electrical
ParameterValue
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltagePower circuit Power circuit 10 MOhm for signalling circuit
[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2
GV2P05KD09G7 — Specifications
ParameterValue
Poles description3P
StandardsNF C 63-650 VDE 0113 IEC 60947-1 VDE 0660 CSA C22.2 IEC 60947-4-1 NF C 63-120 NF C 79-130 IEC 60947-2 EN 60204 UL 508

Product details

The Schneider Electric TeSys GV2P05KD09G7 is a 3-pole manual motor starter rated for 1 A line current, designed for direct on-line motor starting and protection of resistive loads. It's part of the TeSys range, a widely deployed family for motor control in industrial panels and machinery. Motor power rating is 0.25 kW at 400/415 V AC and 0.55 kW at 690 V AC, so it's sized for small motor loads — think fractional-hp pumps, fans, or conveyor drives in a control panel.

The 45 mm width (1.8 in) means it takes a single modular slot on the rail, leaving room for contactor blocks or auxiliaries alongside.

Listed to UL 508, CSA C22.2, IEC 60947-2, IEC 60947-4-1, and EN 60204 — so it's accepted across North American and European installs. Flame retardance is V1 per UL 94; glow-wire tested to 850 °C per IEC 60695-2-1.

Frequently asked questions

What is the breaking capacity of GV2P05KD09G7?

100 kA Icu at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC per IEC 60947-2 — so it's a high-fault-rated starter for a 1 A device.

What standards does GV2P05KD09G7 comply with?

UL 508, CSA C22.2, IEC 60947-2, IEC 60947-4-1, EN 60204, VDE 0660, and NF C 63-650, among others. Flame retardance is V1 per UL 94.

What is the mounting method for GV2P05KD09G7?

Snaps onto 35 mm symmetrical DIN rail or screws to a panel with two M4 screws. Width is 45 mm (1.8 in), one modular DIN slot.

MPN
GV2P05KD09G7