Skip to main content
Schneider Electric GV2P06KD09BL — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2P06KD09BL Motor Starter, 1.6 A, 100 kA

MPNGV2P06KD09BL
Obsolete

Schneider Electric TeSys GV2P06KD09BL motor starter, 1.6 A rated current, 100 kA breaking capacity, 24 V DC coil, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2P06KD09BL — Identification
ParameterValue
Product / component typeMotor starter
GV2P06KD09BL — Mechanical
ParameterValue
Height3.5 in (89 mm)
Width1.8 in (45 mm)
Depth3.8 in (97 mm)
GV2P06KD09BL — Electrical
ParameterValue
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltagePower circuit Power circuit 10 MOhm for signalling circuit
[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2
GV2P06KD09BL — Specifications
ParameterValue
Poles description3P
StandardsIEC 60947-2 IEC 60947-4-1 VDE 0660 UL 508 NF C 79-130 CSA C22.2 VDE 0113 NF C 63-120 EN 60204 IEC 60947-1 NF C 63-650

Product details

It integrates a contactor and thermal-magnetic overload relay in a single 45 mm wide package that clips onto 35 mm symmetrical DIN rail or panels with two M4 screws. Rated for continuous duty per IEC 60947-4-1, it handles motor loads from 0.37 kW at 400 V up to 0.75 kW at 690 V, and covers a motor power range of 1.1 to 2 kW on 200–240 V three-phase supply.

Breaking capacity and protection

The magnetic tripping current is set at 22.5 A, providing short-circuit protection coordinated with the contactor. Breaking capacity reaches 100 kA Icu across all common voltage levels (230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC) per IEC 60947-2 — meaning it can safely interrupt fault currents up to that level without cascading upstream.

Certified to IEC 60947-2, IEC 60947-4-1, UL 508, CSA C22.2, VDE 0660, and EN 60204, among others. Flame retardance is V1 per UL 94, with fire resistance tested to 1562 °F (850 °C) per IEC 60695-2-1. Pollution degree 3 rated, suitable for industrial environments.

Fixes onto 35 mm symmetrical DIN rail or panel with two M4 screws. Screw-clamp terminals accept 1 to 6 mm² solid or flexible wire, with a tightening torque of 15.05 lbf·in (1.7 N·m). IP20 finger-safe protection, IK04 impact resistance.

Frequently asked questions

What is the closest alternative to GV2P06KD09BL in the TeSys family?

Within the TeSys range, the primary difference between GV2P motor starters is the rated current and magnetic trip setting. The GV2P06KD09BL is set for 1.6 A with a 22.5 A magnetic trip; a sibling with a different current rating (e.g., 2.5 A or 4 A) would serve a larger motor but share the same physical footprint and DIN-rail mounting.

What compliance documentation does Schneider provide for GV2P06KD09BL?

The starter carries certifications to IEC 60947-2, IEC 60947-4-1, UL 508, CSA C22.2, VDE 0660, and EN 60204. Flame retardance is V1 per UL 94. Schneider typically provides a Declaration of Conformity and UL/CSA file numbers upon request.

MPN