Skip to main content
Schneider Electric GV2P06KD09G7 — Miniature Circuit Breakers (MCB)

Schneider TeSys GV2P06KD09G7 Motor Starter, 1.6 A, 100 kA Ic

MPNGV2P06KD09G7
Obsolete

Schneider Electric TeSys GV2P06KD09G7, motor starter, 3-pole, 1.6 A rated current, 100 kA Icu breaking capacity at 400 V AC, 0.37 kW at 400 V, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2P06KD09G7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2P06KD09G7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Rated operational voltage (Ue)Power circuit Power circuit 10 MOhm for signalling circuit
Rated insulation voltage (Ui)690 V AC 50/60 Hz IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV IEC 60947-2
Network frequency50/60 Hz IEC 60947-4-1
Utilisation categoryAC-3 AC-1 AC-4
GV2P06KD09G7 — Protection
ParameterValue
Electrical durability (cycles)100000 cycles AC-3 440 V
Mechanical durability (cycles)100000 cycles
GV2P06KD09G7 — Mechanical
ParameterValue
Control typeRotary knob
Terminal connection typescrew clamp terminals 2 0.002...0.009 in² (1...6 mm²) solid screw clamp terminals 2 0.002...0.009 in² (1.5...6 mm²) flexible without cable end screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) flexible with cable end
Terminal tightening torque15.05 lbf.in (1.7 N.m) screw clamp terminals
Width1.8 in (45 mm)
Height3.5 in (89 mm)
Depth3.8 in (97 mm)
GV2P06KD09G7 — Environmental
ParameterValue
Operating ambient temperature23...140 °F (-5...60 °C)
Storage ambient temperature-76...176 °F (-60...80 °C)
IP degree of protectionIP20 IEC 60529
Pollution degree3
GV2P06KD09G7 — Approvals
ParameterValue
StandardsIEC 60947-2 IEC 60947-4-1 VDE 0660 UL 508 NF C 79-130 CSA C22.2 VDE 0113 NF C 63-120 EN 60204 IEC 60947-1 NF C 63-650
GV2P06KD09G7 — Electrical
ParameterValue
[Ics] rated service short-circuit breaking capacity100 % 690 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2

Product details

The Schneider Electric TeSys GV2P06KD09G7 is a 3-pole manual motor starter combining a thermal-magnetic circuit breaker and a contactor in one enclosure, rated for 1.6 A continuous line current. It provides motor protection and switching for three-phase loads up to 0.37 kW at 400/415 V AC and 0.75 kW at 690 V AC, covering AC-3 (motor) and AC-1 (resistive) duty cycles. The magnetic trip is set at 22.5 A, meaning it reacts to short-circuit faults well above the running current, while the thermal element handles overloads.

The 45 mm width (1.8 in) and 89 mm height (3.5 in) fit standard enclosure layouts; depth is 97 mm (3.8 in). IP20 finger-safe terminals allow panel wiring without additional shrouding. Screw-clamp terminals accept 1 to 6 mm² solid or stranded wire; tighten to 1.7 N·m (15 lbf·in). The rotary knob provides manual ON/OFF/reset control directly on the unit.

Certified to IEC 60947-2 (circuit-breaker function), IEC 60947-4-1 (contactor/motor-starter function), UL 508, CSA C22.2, and VDE 0660. The housing meets UL 94 V-1 flame retardance and 850 °C glow-wire test per IEC 60695-2-1.

Frequently asked questions

What is the breaking capacity of this motor starter?

It offers 100 kA Icu at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC per IEC 60947-2, providing high fault-interruption capability across common industrial voltages.

What motor power does the GV2P06KD09G7 cover?

It is rated for 0.37 kW at 400/415 V AC and 0.75 kW at 690 V AC three-phase, with a broader power range from 0 to 6 kW depending on voltage and configuration.

What standards does this part comply with?

It complies with IEC 60947-2, IEC 60947-4-1, UL 508, CSA C22.2, VDE 0660, and EN 60204, among others, covering circuit protection, motor starting, and panel safety requirements.

How is the GV2P06KD09G7 mounted?

It clips onto a 35 mm symmetrical DIN rail or can be panel-mounted with two M4 screws. Dimensions are 45 mm wide, 89 mm high, and 97 mm deep.

MPN