Skip to main content
Schneider Electric GV2P07KD09BL — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2P07KD09BL Motor Starter, 2.5 A, 3P

MPNGV2P07KD09BL
Obsolete

Schneider Electric TeSys GV2P07KD09BL motor starter, 3-pole, 2.5 A line rated current, 100 kA breaking capacity at 400 V AC, 24 V DC low consumption coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2P07KD09BL — Identification
ParameterValue
Product / component typeMotor starter
GV2P07KD09BL — Mechanical
ParameterValue
Height3.5 in (89 mm)
Width1.8 in (45 mm)
Depth3.8 in (97 mm)
GV2P07KD09BL — Electrical
ParameterValue
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 8 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltagePower circuit Power circuit 10 MOhm for signalling circuit
[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2
GV2P07KD09BL — Specifications
ParameterValue
Poles description3P
StandardsVDE 0113 CSA C22.2 EN 60204 IEC 60947-2 IEC 60947-4-1 NF C 79-130 NF C 63-120 NF C 63-650 VDE 0660 UL 508 IEC 60947-1

Product details

The Schneider Electric TeSys GV2P07KD09BL is a 3-pole direct on-line motor starter combining a thermal-magnetic circuit breaker and a contactor in a single 45 mm wide enclosure. It is rated for continuous duty per IEC 60947-4-1 and carries a line rated current of 2.5 A, with magnetic tripping set at 33.5 A.

Motor power coverage and utilization categories

Rated for AC-3 (squirrel-cage motor starting), AC-1 (resistive), and AC-4 (plugging/inching) duty. Motor power ratings span 0.75 kW at 400/415 V up to 1.5 kW at 690 V. The 24 V DC low-consumption coil holds in without the heat of an AC coil, which matters in densely packed enclosures where thermal rise is a constraint.

The 45 mm width (1.8 in) and 97 mm depth (3.8 in) fit standard distribution board spacing. Screw-clamp terminals accept 1 to 6 mm² solid or stranded wire; tighten to 1.7 N·m.

Certified to IEC 60947-2 (circuit-breaker function), IEC 60947-4-1 (contactor/motor-starter), UL 508, CSA C22.2, and EN 60204. The standards list covers the major industrial markets — IEC for Europe/global, UL/CSA for North America.

Frequently asked questions

What is the closest alternative to the GV2P07KD09BL in the TeSys family?

Within the TeSys GV2P range, the closest sibling is the GV2P07 (without the KD09BL suffix), which shares the same 2.5 A thermal setting and 3-pole frame but uses a standard AC coil voltage rather than the 24 V DC low-consumption coil. The deciding factor between them is the coil voltage — the KD09BL variant is for DC control circuits where low holding power is required.

What compliance documentation is available for the GV2P07KD09BL?

The part carries certifications to IEC 60947-2, IEC 60947-4-1, UL 508, CSA C22.2, EN 60204, and VDE 0660. Schneider typically provides Declaration of Conformity (CE), UL/CSA listing cards, and material compliance data (RoHS/REACH) through their product documentation portal.

MPN
GV2P07KD09BL