Schneider Electric GV2P08KD09B7 — Miniature Circuit Breakers (MCB)

Schneider Electric GV2P08KD09B7 TeSys Motor Starter, 4 A, 10

MPNGV2P08KD09B7
Obsolete

Schneider Electric TeSys GV2P08KD09B7, direct on-line motor starter, 4 A rated, 100 kA breaking capacity at 400 V AC, 24 V AC coil, 3-pole, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2P08KD09B7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2P08KD09B7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 8 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Rated operational voltage (Ue)Power circuit Power circuit 10 MOhm for signalling circuit
Rated insulation voltage (Ui)690 V AC 50/60 Hz IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV IEC 60947-2
Network frequency50/60 Hz IEC 60947-4-1
Utilisation categoryAC-4 AC-1 AC-3
GV2P08KD09B7 — Protection
ParameterValue
Electrical durability (cycles)100000 cycles AC-3 440 V
Mechanical durability (cycles)100000 cycles
GV2P08KD09B7 — Mechanical
ParameterValue
Control typeRotary knob
Terminal connection typescrew clamp terminals 2 0.002...0.009 in² (1...6 mm²) solid screw clamp terminals 2 0.002...0.009 in² (1.5...6 mm²) flexible without cable end screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) flexible with cable end
Terminal tightening torque15.05 lbf.in (1.7 N.m) screw clamp terminals
Width1.8 in (45 mm)
Height3.5 in (89 mm)
Depth3.8 in (97 mm)
GV2P08KD09B7 — Environmental
ParameterValue
Operating ambient temperature23...140 °F (-5...60 °C)
Storage ambient temperature-76...176 °F (-60...80 °C)
IP degree of protectionIP20 IEC 60529
Pollution degree3
GV2P08KD09B7 — Approvals
ParameterValue
StandardsVDE 0660 CSA C22.2 VDE 0113 EN 60204 NF C 63-650 NF C 79-130 NF C 63-120 IEC 60947-4-1 IEC 60947-1 UL 508 IEC 60947-2
GV2P08KD09B7 — Electrical
ParameterValue
[Ics] rated service short-circuit breaking capacity100 % 690 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2

Product details

That 4 A figure is the continuous current the main poles carry; pair it with a motor drawing up to that full-load amp rating. The magnetic trip point is set at 51 A, so short-circuit faults above that level trip instantly without waiting for the thermal bimetal. The breaking capacity is what makes this part stand out: 100 kA Icu at 230/240 V, 400/415 V, 440 V, and 500 V AC. These ratings are per IEC 60947-2, the standard for circuit-breaker performance in industrial applications. The motor power range covers 1.1 kW at 400/415 V up to 2.2 kW at 690 V, so it fits small pumps, fans, conveyors, or compressors in that power band.

Mounting and integration — DIN rail or panel screw

At 45 mm wide, it takes up one standard modular slot — leaves room alongside a TeSys GV2 or GV7 breaker for a coordinated starter combination. The screw-clamp terminals accept 1 to 6 mm² solid or 1.5 to 6 mm² flexible wire; torque them to 1.7 N·m (15 lbf·in). IP20 finger-safe means it's protected against accidental contact inside the enclosure, but not against washdown — keep it inside a rated cabinet.

Frequently asked questions

What compliance documentation does this part carry?

It is certified to IEC 60947-4-1, IEC 60947-2, UL 508, CSA C22.2, VDE 0660, and VDE 0113. The housing is UL 94 V1 flame retardant and glow-wire tested to 850 °C.

What is the breaking capacity at 400 V?

100 kA Icu at 400/415 V AC 50/60 Hz per IEC 60947-2. At 690 V it drops to 8 kA.

What wire sizes does the screw-clamp terminal accept?

Solid: 1 to 6 mm². Flexible without ferrule: 1.5 to 6 mm². Flexible with ferrule: 1 to 4 mm². Torque to 1.7 N·m.

MPN
GV2P08KD09B7