Skip to main content
Schneider Electric GV2P10KD09B7 — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2P10KD09B7 Motor Starter, 6.3 A, 100 kA

MPNGV2P10KD09B7
Obsolete

Schneider Electric TeSys GV2P10KD09B7 motor starter, 3-pole, 6.3 A line rated current, 100 kA breaking capacity at 400 V, 24 V AC coil, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2P10KD09B7 — Identification
ParameterValue
Product / component typeMotor starter
GV2P10KD09B7 — Mechanical
ParameterValue
Height3.5 in (89 mm)
Width1.8 in (45 mm)
Depth3.8 in (97 mm)
GV2P10KD09B7 — Electrical
ParameterValue
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltagePower circuit Power circuit 10 MOhm for signalling circuit
[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2
GV2P10KD09B7 — Specifications
ParameterValue
Poles description3P
StandardsIEC 60947-4-1 CSA C22.2 VDE 0113 VDE 0660 UL 508 IEC 60947-1 NF C 79-130 NF C 63-120 EN 60204 IEC 60947-2 NF C 63-650

Product details

The Schneider Electric TeSys GV2P10KD09B7 is a direct on-line motor starter combining a contactor and thermal-magnetic overload relay in one 45 mm wide package. It's rated for continuous duty per IEC 60947-4-1 and carries a line rated current of 6.3 A. The 6.3 A rating means this starter handles motor loads up to 2.2 kW at 400/415 V, 3 kW at 500 V, or 4 kW at 690 V — the motor power the buyer should match to their load.

The IP20 finger-safe enclosure suits control panel use — not washdown environments. The 24 V AC coil is standard; the rotary knob provides local manual control. Screw-clamp terminals accept 1 to 6 mm² solid or stranded wire, torqued to 1.7 N·m.

Compliance covers IEC 60947-4-1, CSA C22.2, UL 508, and VDE 0660 — accepted in North American and European panels without additional paperwork.

Frequently asked questions

What are the key ratings I need to match for my motor?

Line rated current is 6.3 A, with motor power ratings of 2.2 kW at 400/415 V, 3 kW at 500 V, and 4 kW at 690 V. Breaking capacity is 100 kA at 400 V.

What compliance certifications does this carry?

It is certified to IEC 60947-4-1, CSA C22.2, UL 508, VDE 0660, and EN 60204, among others.

MPN