Schneider Electric GV2P16TQ — Miniature Circuit Breakers (MCB)

Schneider Electric GV2P16TQ Motor Circuit Breaker, 14 A, TeS

MPNGV2P16TQ
Obsolete

Schneider Electric TeSys Deca GV2P motor circuit breaker, GV2P16TQ, 14 A rated current, thermal-magnetic, 3-pole, 100 kA breaking capacity at 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2P16TQ — Identification
ParameterValue
Product nameTeSys GV2
Product rangeTeSys Deca
Product/component typeMotor circuit breaker
Device applicationMotor protection
GV2P16TQ — Ratings
ParameterValue
Rated current (In)14 A
Poles configuration3P
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage (Ui)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz conforming to IEC 60947-2
Utilisation categoryCategory A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1
GV2P16TQ — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to IEC 60947-1
Electrical durability (cycles)100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In
Mechanical durability (cycles)100000 cycles
GV2P16TQ — Mechanical
ParameterValue
Control typeRotary handle
Terminal connection typePower circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end
Terminal tightening torque1.7 N.m - on screw clamp terminal
Width45 mm
Height89 mm
Depth97 mm
GV2P16TQ — Environmental
ParameterValue
Operating ambient temperature-20...60 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
GV2P16TQ — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2
GV2P16TQ — Electrical
ParameterValue
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2

Product details

Its thermal-magnetic trip unit combines a bimetal overload element with a magnetic short-circuit trip set at 253.4 A, providing coordinated protection for motor branch circuits. Phase failure sensitivity is built in, conforming to IEC 60947-4-1, so it will trip on loss of one phase — critical for preventing single-phasing damage on three-phase motors. The part is certified for isolation per IEC 60947-1, meaning it can serve as a disconnecting means under load when the handle is in the OFF position.

Rated at 14 A In, this breaker matches motor full-load currents up to approximately 5.5 kW at 400/415 V AC — the motor power table shows 5.5 kW at 400/415 V, 7.5 kW at 500 V, and 9 kW / 11 kW at 690 V depending on the winding configuration. Breaking capacity is 100 kA Icu at 400/415 V AC per IEC 60947-2, meaning it can safely interrupt a fault current up to 100 kA at that voltage without failing. This is a high-interrupting rating for a compact motor-protective device, suitable for installations with high available fault current. The utilisation category is AC-3 and AC-3e per IEC 60947-4-1, which covers starting and stopping of squirrel-cage motors — the standard duty for a motor circuit breaker. Electrical durability is rated at 100,000 cycles under AC-3 at 415 V at rated current — this is the number of on-load operations before the contacts need replacement. Mechanical durability matches at 100,000 cycles.

Power connections accept screw-clamp terminals: up to 2 x 6 mm² solid or 2 x 4 mm² flexible with ferrule. Tightening torque is 1.7 N·m.

The GV2P16TQ carries declarations of conformity to EN/IEC 60947-2 (circuit-breakers), EN/IEC 60947-4-1 (motor-starters), UL 60947-4-1, and CSA C22.2 No 60947-4-1. It also meets IEC/EN 60335-2-40 Annex JJ and IEC/EN 60335-1 Clause 30.2 for glow-wire / fire resistance at 960 °C per IEC 60695-2-11. Climatic withstand conforms to IACS, and mechanical robustness is specified at 30 Gn shock for 11 ms and 5 Gn vibration from 5 to 150 Hz — suitable for industrial environments with moderate mechanical stress.

Frequently asked questions

What are the key standards this part is certified to?

It carries declarations of conformity to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335 series clauses for fire resistance and appliance safety.

What is the closest alternative within the TeSys Deca family?

The GV2P16TQ is the 14 A thermal-magnetic variant in the GV2P range. The closest sibling is the GV2P14TQ (10 A) for lower-current motors, or the GV2P20TQ (18 A) for slightly higher loads. All share the same 45 mm footprint, DIN-rail mounting, and terminal layout, so swapping requires only adjusting the overload setting.

What is the depth of this component?

The depth is 97 mm, with a width of 45 mm and height of 89 mm.

What is the product range name?

It belongs to the TeSys Deca range, specifically the TeSys GV2 series of motor circuit breakers.