Schneider Electric GV2P20KD25B7 — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2P20KD25B7 Motor Starter, 18 A, 7.5 kW

MPNGV2P20KD25B7
Obsolete

Schneider Electric TeSys GV2P20KD25B7 motor starter, 3-pole, 18 A line rated, 7.5 kW at 400 V, 24 V AC coil, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2P20KD25B7 — Identification
ParameterValue
Product / component typeMotor starter
GV2P20KD25B7 — Mechanical
ParameterValue
Height3.5 in (89 mm)
Width1.8 in (45 mm)
Depth3.8 in (97 mm)
GV2P20KD25B7 — Electrical
ParameterValue
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 4 kA Icu 690 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltagePower circuit Power circuit 10 MOhm for signalling circuit
[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2
GV2P20KD25B7 — Specifications
ParameterValue
Poles description3P
StandardsUL 508 IEC 60947-1 IEC 60947-2 EN 60204 NF C 79-130 NF C 63-120 NF C 63-650 IEC 60947-4-1 CSA C22.2 VDE 0113 VDE 0660

Product details

The Schneider Electric TeSys GV2P20KD25B7 is a direct on-line motor starter combining a contactor and thermal-magnetic overload relay in a single 45 mm wide package. It is rated for 18 A line current and handles motor loads up to 7.5 kW at 400/415 V AC or 15 kW at 690 V AC, making it a fit for three-phase induction motors driving pumps, conveyors, and compressors in industrial control panels. The magnetic trip is set at 223 A, providing short-circuit protection coordinated with the thermal overload curve. Breaking capacity reaches 100 kA Icu at 230/240 V and 50 kA at 400/415 V per IEC 60947-2, which means it can safely interrupt high fault currents without upstream fuses in most distribution scenarios. The unit clips onto 35 mm symmetrical DIN rail or mounts with two M4 screws — the DIN rail option keeps panel layout flexible and speeds replacement.

This starter carries approvals under UL 508, IEC 60947-1, IEC 60947-2, IEC 60947-4-1, CSA C22.2, and EN 60204, covering the major North American and European industrial control standards.

At 45 mm wide and 89 mm tall, the GV2P20KD25B7 occupies a single modular DIN-rail pitch, leaving room for auxiliary contact blocks or a separate control transformer on the same rail. Screw-clamp terminals accept 1 to 6 mm² solid or stranded wire, torqued to 1.7 N·m. Rated for continuous duty per IEC 60947-4-1 with an electrical durability of 100,000 cycles in AC-3 at 440 V and mechanical durability of 100,000 cycles. The maximum operating rate of 25 cycles per hour is adequate for most motor starting applications but should be checked against frequent jogging or inching duty.

Frequently asked questions

What are the key ratings for this motor starter?

The GV2P20KD25B7 is rated 18 A line current, handles motors up to 7.5 kW at 400/415 V or 15 kW at 690 V, has a magnetic trip at 223 A, and a breaking capacity of 50 kA Icu at 400/415 V per IEC 60947-2. The coil is 24 V AC.

What compliance documentation does this part carry?

It is certified to UL 508, IEC 60947-1, IEC 60947-2, IEC 60947-4-1, CSA C22.2, EN 60204, and VDE 0660, covering North American and European industrial control standards. The enclosure is IP20 per IEC 60529.

How is this motor starter mounted?

It clips onto 35 mm symmetrical DIN rail or can be panel-mounted with two M4 screws. The 45 mm width fits standard modular DIN-rail spacing.

MPN