Specifications

GV2P20KD25BL — Identification
ParameterValue
Product / component typeMotor starter
GV2P20KD25BL — Mechanical
ParameterValue
Height3.5 in (89 mm)
Width1.8 in (45 mm)
Depth3.8 in (97 mm)
GV2P20KD25BL — Electrical
ParameterValue
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 4 kA Icu 690 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltagePower circuit Power circuit 10 MOhm for signalling circuit
[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2
GV2P20KD25BL — Specifications
ParameterValue
Poles description3P
StandardsUL 508 IEC 60947-1 IEC 60947-2 EN 60204 NF C 79-130 NF C 63-120 NF C 63-650 IEC 60947-4-1 CSA C22.2 VDE 0113 VDE 0660

Product details

The Schneider Electric TeSys GV2P20KD25BL is a direct on-line motor starter combining a contactor and thermal-magnetic overload relay in a single 3-pole package. It is rated for continuous duty per IEC 60947-4-1 and carries a line rated current of 18 A. The IP20 degree of protection means it is suited for installation inside a cabinet, not exposed to washdown. It is designed for motor control and resistive loads, with utilisation categories AC-1, AC-3, and AC-4 covering resistive, squirrel-cage motor starting, and plugging/inching duties respectively.

The breaking capacity (Icu) per IEC 60947-2 is 100 kA at 230/240 V AC, 50 kA at 400/415 V AC, 20 kA at 440 V AC, 10 kA at 500 V AC, and 4 kA at 690 V AC. The magnetic tripping current is set at 223 A, providing short-circuit protection for the motor branch circuit. The 18 A line rated current sets the continuous ampacity for the thermal overload element. The control coil is 24 V DC low consumption, which is a common safety voltage for control circuits and reduces heat dissipation inside the panel compared to AC coils.

Standards Compliance and Lifecycle

This motor starter complies with UL 508, IEC 60947-1, IEC 60947-2, IEC 60947-4-1, CSA C22.2, and EN 60204, among others. This means it is accepted for use in North American and European installations without additional certification hurdles.

Frequently asked questions

What are the key dimensions for panel layout?

The GV2P20KD25BL has a depth of 3.8 in (97 mm), a width of 1.8 in (45 mm), and a height of 3.5 in (89 mm).

What compliance documentation is available for this part?

The GV2P20KD25BL is certified to UL 508, IEC 60947-1, IEC 60947-2, IEC 60947-4-1, CSA C22.2, EN 60204, and several other national standards. The manufacturer provides declarations of conformity and certificates for these standards.

What is the closest alternative to the GV2P20KD25BL in the TeSys range?

Within the TeSys range, the closest alternative would be a model with the same frame size and similar ratings but possibly a different coil voltage or auxiliary contact configuration. For a direct replacement, verify the line rated current (18 A) and coil voltage (24 V DC) match your BOM.