Skip to main content
Schneider Electric GV2P20KD25G7 — Miniature Circuit Breakers (MCB)

TeSys GV2P20KD25G7 motor starter, 18 A, 7.5 kW at 400 V

MPNGV2P20KD25G7
Obsolete

Schneider Electric TeSys GV2P20KD25G7, motor starter, 3 poles, 18 A rated current, 7.5 kW at 400 V, 100 kA breaking capacity, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2P20KD25G7 — Identification
ParameterValue
Product rangeTeSys
Product/component typeMotor starter
GV2P20KD25G7 — Ratings
ParameterValue
Poles configuration3P
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 4 kA Icu 690 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
Rated operational voltage (Ue)Power circuit Power circuit 10 MOhm for signalling circuit
Rated insulation voltage (Ui)690 V AC 50/60 Hz IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV IEC 60947-2
Network frequency50/60 Hz IEC 60947-4-1
Utilisation categoryAC-3 AC-4 AC-1
GV2P20KD25G7 — Protection
ParameterValue
Electrical durability (cycles)100000 cycles AC-3 440 V
Mechanical durability (cycles)100000 cycles
GV2P20KD25G7 — Mechanical
ParameterValue
Control typeRotary knob
Terminal connection typescrew clamp terminals 2 0.002...0.009 in² (1...6 mm²) solid screw clamp terminals 2 0.002...0.009 in² (1.5...6 mm²) flexible without cable end screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) flexible with cable end
Terminal tightening torque15.05 lbf.in (1.7 N.m) screw clamp terminals
Width1.8 in (45 mm)
Height3.5 in (89 mm)
Depth3.8 in (97 mm)
GV2P20KD25G7 — Environmental
ParameterValue
Operating ambient temperature23...140 °F (-5...60 °C)
Storage ambient temperature-76...176 °F (-60...80 °C)
IP degree of protectionIP20 IEC 60529
Pollution degree3
GV2P20KD25G7 — Approvals
ParameterValue
StandardsUL 508 IEC 60947-1 IEC 60947-2 EN 60204 NF C 79-130 NF C 63-120 NF C 63-650 IEC 60947-4-1 CSA C22.2 VDE 0113 VDE 0660
GV2P20KD25G7 — Electrical
ParameterValue
[Ics] rated service short-circuit breaking capacity100 % 690 V AC 50/60 Hz IEC 60947-2 100 % 230/240 V AC 50/60 Hz IEC 60947-2 75 % 500 V AC 50/60 Hz IEC 60947-2 50 % 400/415 V AC 50/60 Hz IEC 60947-2 75 % 440 V AC 50/60 Hz IEC 60947-2

Product details

The Schneider Electric TeSys GV2P20KD25G7 is a direct-on-line motor starter with a rotary knob control, integrating a 3-pole contactor and thermal-magnetic protection into a single 45 mm wide unit for DIN-rail or panel mounting. Rated at 18 A line current, this starter handles 7.5 kW at 400/415 V AC and up to 15 kW at 690 V AC in AC-3 duty. The magnetic trip is set at 223 A, covering motor inrush without nuisance tripping on start. Breaking capacity reaches 100 kA at 230/240 V (Icu per IEC 60947-2), dropping to 50 kA at 400/415 V and 4 kA at 690 V.

Clips onto 35 mm symmetrical DIN rail or mounts directly to the panel with two M4 screws. At 45 mm wide and 89 mm tall, three of these fit in a standard 150 mm enclosure depth with room for cable entry below. Screw-clamp terminals accept 1 to 6 mm² solid or stranded wire. Tighten to 1.7 N·m — no special tooling needed for a panel builder. Rated IP20, so it's for inside the enclosure only. Pollution degree 3 means it handles conductive dust and condensation in typical industrial cabinets.

Compliance is broad: UL 508, IEC 60947-1/2/4-1, CSA C22.2, EN 60204, and VDE 0660. That covers North American, European, and many Asian regulatory gates in one part number.

Frequently asked questions

What compliance documentation does this part carry?

It complies with UL 508, IEC 60947-1, IEC 60947-2, IEC 60947-4-1, CSA C22.2, EN 60204, and VDE 0660. Flame retardance is V1 per UL 94.

What motor power does this starter cover?

It is rated for 7.5 kW at 400/415 V, 9 kW at 500 V, and 15 kW at 690 V, all AC-3 duty. The motor power range covers 4–6 kW at 200–240 V and 15–25 kW at 525–690 V.

What is the breaking capacity at 400 V?

50 kA Icu at 400/415 V AC per IEC 60947-2. That is sufficient for most industrial distribution without upstream fuses.

MPN
GV2P20KD25G7