Schneider Electric GV2RT03AE11TQ — Molded Case Circuit Breakers (MCCB)

Schneider GV2RT03AE11TQ TeSys GV2 Motor Circuit Breaker, 0.4

MPNGV2RT03AE11TQ
Obsolete

Schneider Electric TeSys GV2 motor circuit breaker, GV2RT03AE11TQ, 0.4 A rated current, thermal-magnetic trip, 3-pole, 100 kA breaking capacity, screw clamp terminals, 1 NO + 1 NC auxiliary contacts.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2RT03AE11TQ — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection Transformer
GV2RT03AE11TQ — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth78.5 mm
GV2RT03AE11TQ — Electrical
ParameterValue
[In] rated current0.4 A
Breaking capacity100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2RT03AE11TQ — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2RT
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1

Product details

The GV2RT03AE11TQ is a TeSys GV2 motor circuit breaker from Schneider Electric's TeSys Deca range, rated at 0.4 A continuous current (In) with a thermal-magnetic trip unit. That 0.4 A is the continuous rating that governs the motor protection curve — it's sized for a 0.06 kW motor at 230 V or 0.09 kW at 400 V, so the breaker's thermal element tracks the motor's heating characteristic, not just a generic branch circuit. The magnetic trip is set at 8 A, so the instantaneous short-circuit pickup is 20× the thermal rating. This is typical for motor-starting inrush. Breaking capacity is a flat 100 kA Icu across the voltage range from 230 V to 690 V AC, certified to IEC 60947-2.

The 78.5 mm depth leaves clearance in a standard enclosure. The front-mounted toggle provides manual on/off control and a trip-indicated position. The auxiliary contact block — 1 NO + 1 NC — is integrated into the front, so you get a remote status signal without an add-on module, useful for a PLC input or a seal-in circuit.

The 100 000-cycle electrical durability at AC-3 and AC-3e duty (at 415 V, full rated current) and matching mechanical endurance mean this breaker is rated for the life of a typical conveyor or pump motor in a production line — not a one-shot device.

Certified to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (contactor-starter standard for motor protection), with suitability for isolation per IEC 60947-1. Climatic withstand conforms to IACS for marine environments, and the 960 °C glow-wire test per IEC 60695-2-11 covers fire resistance in the panel.

Frequently asked questions

What is the closest alternative to the GV2RT03AE11TQ in the TeSys GV2 family?

The standard single-unit order code GV2RT03 is the same breaker without the bulk-pack quantity (set of 24). The electrical ratings — 0.4 A In, 8 A magnetic trip, 100 kA breaking capacity — are identical. The choice is purely packaging: the AE11TQ suffix denotes the 24-piece tray, which matters only if you're filling a BOM line for multiple panels.

What compliance documentation does Schneider provide for this part?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60947-4-1, with suitability for isolation per IEC 60947-1. Climatic withstand conforms to IACS (marine). The fire-resistance rating is 960 °C per IEC 60695-2-11.