Skip to main content
Schneider Electric GV2RT043 — Molded Case Circuit Breakers (MCCB)

GV2RT043 TeSys Deca Motor Circuit Breaker, 0.63 A, 100 kA

MPNGV2RT043
Obsolete

Schneider Electric TeSys Deca GV2RT043, motor circuit breaker, 3P, 0.63 A rated current, thermal-magnetic trip, 100 kA Icu at 400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2RT043 — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection Transformer
GV2RT043 — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth78.5 mm
GV2RT043 — Electrical
ParameterValue
[In] rated current0.63 A
Breaking capacity100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2RT043 — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2RT
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1

Product details

The GV2RT043 is a 3-pole motor circuit breaker from the TeSys Deca range, rated at 0.63 A with a thermal protection adjustment range of 0.4...0.63 A.

The 45 mm width and 89 mm height keep it compact for a crowded enclosure. Spring terminals on the power circuit accept 1...6 mm² solid or 1.5...4 mm² flexible with cable end — no screwdriver torque check needed, which speeds up panel wiring.

Motor protection ratings

Rated for motor protection at 0.12 kW at 400/415 V AC and 0.37 kW at 690 V AC. The utilisation category is AC-3 and AC-3e per IEC 60947-4-1, which means it's designed for starting and stopping squirrel-cage motors — the AC-3e suffix indicates enhanced electrical durability for high-cycle applications. Electrical durability is rated at 100,000 cycles for AC-3 at 415 V In, matching the mechanical durability figure.

Frequently asked questions

What are the key ratings for GV2RT043?

Rated current 0.63 A, thermal protection adjustment range 0.4...0.63 A, breaking capacity 100 kA Icu at 400/415 V AC, rated operational voltage 690 V AC, and it meets EN/IEC 60947-2 and EN/IEC 60947-4-1.

What compliance documentation does Schneider Electric provide for GV2RT043?

The part is certified to EN/IEC 60947-2 and EN/IEC 60947-4-1, and carries a fire resistance rating of 960 °C per IEC 60695-2-11. Climatic withstand conforms to IACS. The IP degree of protection is IP20 per IEC 60529.

MPN