Schneider Electric GV2RT053 — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2RT053 Motor Circuit Breaker, 1 A, 100 kA

MPNGV2RT053
Obsolete

Schneider Electric TeSys Deca GV2RT053 motor circuit breaker, 3-pole, thermal-magnetic, In 1 A, 100 kA breaking capacity, spring terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2RT053 — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection Transformer
GV2RT053 — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth78.5 mm
GV2RT053 — Electrical
ParameterValue
[In] rated current1 A
Breaking capacity100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2RT053 — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2RT
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1

Product details

It provides motor and transformer protection, with a thermal adjustment range of 0.63...1 A, so the 1 A setting is the top end of the adjustment band — set it to match the motor full-load current, not the breaker's own rating. Breaking capacity is 100 kA Icu across the full voltage range (220...690 V AC, 50/60 Hz), certified to IEC 60947-2.

The 45 mm width and 89 mm height keep the panel fill factor tight — three of these side by side take 135 mm of rail. Spring terminals accept 1...6 mm² solid or 1.5...4 mm² flexible with cable end, so it wires directly into the motor branch circuit without lug adaptors. IP20 finger-safe enclosure (IK04 impact rating) suits it for enclosed panels, not washdown zones. Ambient operating range -20...60 °C, storage -40...80 °C, with 2.5 W power dissipation per pole — factor that into enclosure thermal calculations if you're packing several breakers in a small cabinet.

Rated operational voltage (Ue) 690 V AC, insulation voltage (Ui) 690 V AC, impulse withstand (Uimp) 6 kV. Suitability for isolation per IEC 60947-1 — it can serve as a disconnecting means in the motor circuit. Electrical durability 100,000 cycles at AC-3/AC-3e at 415 V; mechanical durability 100,000 cycles. Magnetic trip fixed at 22 A, so short-circuit protection is independent of the thermal dial. Motor power ratings span 0.09 kW at 230 V up to 0.55 kW at 690 V (high peak current motor protection), and up to 1 kW for transformer protection at 690 V. The 1 A thermal setting covers small motors and control transformers in the sub-1 kW range.

Frequently asked questions

What is the closest alternative to GV2RT053 in the same family?

Within the TeSys Deca GV2RT range, the closest peer is the GV2RT05 (0.63...1 A thermal adjustment, same 1 A In) — functionally identical for the 1 A setting. The GV2RT053 is the standard order code; the GV2RT05 may be a different packaging or regional variant. Confirm the exact order code against your BOM before substituting.