Schneider Electric GV2RT063 — Molded Case Circuit Breakers (MCCB)

Schneider Electric GV2RT063 TeSys GV2 Motor Circuit Breaker,

MPNGV2RT063
Obsolete

Schneider Electric TeSys Deca GV2RT063, 3-pole motor circuit breaker, thermal-magnetic, 1.6 A rated current, 100 kA breaking capacity at 400 V, spring terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2RT063 — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection Transformer
GV2RT063 — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth78.5 mm
GV2RT063 — Electrical
ParameterValue
[In] rated current1.6 A
Breaking capacity100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2RT063 — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2RT
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1

Product details

The Schneider Electric GV2RT063 is a TeSys Deca GV2 motor circuit breaker — a 3-pole thermal-magnetic device rated 1.6 A continuous, with an adjustable thermal protection range of 1...1.6 A. It's built to protect motor and transformer loads per IEC 60947-2 and IEC 60947-4-1, with a 100 kA interrupting capacity at 400 V AC that holds all the way to 690 V. The thermal-magnetic trip unit handles both overload (thermal) and short-circuit (magnetic) events. The magnetic trip is fixed at 33 A, so it rides through motor inrush without nuisance tripping but still clears a hard fault fast. Rated for AC-3 and AC-3e duty categories, meaning it's certified for switching squirrel-cage motors under load — the most common motor-starting regime in industrial panels.

Mounting and wiring — panel fit

At 45 mm wide and 89 mm tall, it fits standard motor-starter footprints in a control cabinet. The spring-cage terminals on the power circuit accept 1...6 mm² solid or 1.5...4 mm² flexible with ferrule — two conductors per terminal, so daisy-chaining the line side is straightforward. No screw torque to verify; the spring holds the conductor captive. Rated IP20 finger-safe on the front, IK04 impact resistance. The 78.5 mm depth leaves clearance behind a standard 100 mm deep enclosure door. Ambient operating range is -20 to 60 °C, storage -40 to 80 °C, with a fire-resistance rating of 960 °C per IEC 60695-2-11. Suitable for isolation per IEC 60947-1 — you can lock it off for downstream work.

Motor power coverage

At 1.6 A thermal setting, this breaker covers small motors: 0.37 kW at 400/415 V AC (high peak current motor protection), 0.55 kW at 500 V, and up to 1.1 kW at 690 V. For transformer protection, it covers 0.63 kVA at 400/415 V. The power dissipation per pole is 2.5 W — about 7.5 W total at full load, which matters for thermal rise in a densely packed DIN-rail row.

Frequently asked questions

What is the breaking capacity of the GV2RT063?

The GV2RT063 has a 100 kA Icu breaking capacity at 220/230 V, 400/415 V, 440 V, 500 V, and 690 V AC per IEC 60947-2. That's a high-interrupting rating that holds across the voltage range, so it clears faults without upstream fuses needing to operate in most panel configurations.

What wire sizes does the spring terminal accept?

The power circuit spring terminals accept 1...6 mm² solid wire, or 1.5...4 mm² flexible without ferrule, or 1...4 mm² flexible with ferrule. Two conductors per terminal are allowed, which simplifies daisy-chaining the line side in a motor starter group.

What compliance documentation does Schneider provide for the GV2RT063?

The GV2RT063 is certified to EN/IEC 60947-2 and EN/IEC 60947-4-1, with a suitability-for-isolation marking per IEC 60947-1. The climatic withstand conforms to IACS. Standard Schneider documentation includes the declaration of conformity, CE marking, and UL/CSA file numbers available through the Schneider portal.