Schneider Electric GV2RT06AE11TQ — Molded Case Circuit Breakers (MCCB)

TeSys GV2RT06AE11TQ Motor Circuit Breaker, 1.6 A, 100 kA

MPNGV2RT06AE11TQ
Obsolete

Schneider Electric TeSys Deca GV2RT06AE11TQ, motor circuit breaker, 3-pole, 1.6 A rated current, thermal-magnetic trip, 100 kA breaking capacity, 1 NO + 1 NC auxiliary contacts.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2RT06AE11TQ — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection Transformer
GV2RT06AE11TQ — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth78.5 mm
GV2RT06AE11TQ — Electrical
ParameterValue
[In] rated current1.6 A
Breaking capacity100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2RT06AE11TQ — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2RT
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1

Product details

The Schneider Electric GV2RT06AE11TQ is a TeSys Deca GV2RT series motor circuit breaker, 3-pole, rated 1.6 A with a thermal-magnetic trip unit. The 1.6 A rating means this breaker protects small motors — it covers motor power from 0.18 kW at 230 V up to 1.1 kW at 690 V, depending on the supply voltage and whether it's motor or transformer duty. The thermal-magnetic trip gives both overload (thermal) and short-circuit (magnetic) protection in one device. That's useful for panels with high available fault current.

Accepts horizontal or vertical orientation. Power connections are screw-clamp terminals accepting up to 2 x 6 mm² solid or 2 x 4 mm² flexible with ferrule. The toggle control type gives manual on/off and trip-reset capability right on the front face. IK04 impact resistance handles incidental tool bumps during commissioning.

It's part of the TeSys Deca family, a widely used motor protection platform with good cross-reference support. The GV2RT06AE11TQ is the 1.6 A variant with auxiliary contacts included — the base GV2RT06 without the 'TQ' suffix omits the aux contacts.

Key ratings in context

Magnetic trip threshold is 33 A, about 20x the In, giving good short-circuit discrimination for motor starting inrush. Electrical durability is 100,000 cycles at AC-3 duty (415 V at rated current), matching the mechanical durability of 100,000 cycles. Power dissipation is 2.5 W per pole — 7.5 W total at full load, manageable in a standard enclosure. Climatic withstand conforms to IACS for marine and humid environments.

Frequently asked questions

What is the breaking capacity of GV2RT06AE11TQ?

100 kA Icu at all rated voltages from 230 V to 690 V AC, conforming to IEC 60947-2. That's consistent across the full voltage range, not just at one voltage.

What auxiliary contacts does this breaker include?

It includes 1 normally-open and 1 normally-closed front-mounted auxiliary contact. The 'TQ' suffix in the order code indicates these are factory-fitted.

What standards does GV2RT06AE11TQ comply with?

It conforms to EN/IEC 60947-2 for circuit-breaker performance and EN/IEC 60947-4-1 for motor-starter coordination. It also meets IEC 60695-2-11 glow-wire test at 960 °C and is suitable for isolation per IEC 60947-1.