Skip to main content
Schneider Electric GV2RT07AE11TQ — Molded Case Circuit Breakers (MCCB)

Schneider TeSys GV2RT07AE11TQ Motor Circuit Breaker, 2.5 A,

MPNGV2RT07AE11TQ
Obsolete

Schneider Electric TeSys Deca GV2RT07AE11TQ, motor circuit breaker, 3-pole, 2.5 A rated current, thermal-magnetic, 100 kA breaking capacity at 400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2RT07AE11TQ — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection Transformer
GV2RT07AE11TQ — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth78.5 mm
GV2RT07AE11TQ — Electrical
ParameterValue
[In] rated current2.5 A
Breaking capacity100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2RT07AE11TQ — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2RT
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1

Product details

It's designed for motor and transformer protection, with a magnetic tripping current of 51 A that clears short circuits fast enough to protect downstream contactors and cable runs. That's a high-interrupting rating for a compact 45 mm wide device — it handles most industrial supply transformers without needing a current-limiting upstream breaker. It carries motor power ratings from 0.37 kW at 230 V up to 1.5 kW at 690 V, and transformer protection ratings up to 2 kW at 690 V. The utilisation category is AC-3 and AC-3e per IEC 60947-4-1, so it's rated for starting and stopping squirrel-cage motors under load — not just resistive switching.

It ships with 1 NO + 1 NC auxiliary contacts built into the front face, so you get status feedback without adding a separate aux block. Power connections accept up to 6 mm² solid or 4 mm² flexible with ferrule, torqued to 1.7 N·m. The IK04 impact rating means it survives the odd dropped tool during commissioning.

The set quantity is 24 units, which matches the typical panel-builder batch for a multi-motor control cabinet.

Certified to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (contactor/motor-starter standard), so it qualifies as both a branch-circuit protective device and a motor-protective device under IEC. Fire resistance tested to 960 °C per IEC 60695-2-11, and climatic withstand conforms to IACS for marine-environment humidity cycling. Operating altitude is limited to 2000 m without derating.

Frequently asked questions

What are the key ratings for this motor circuit breaker?

Rated current is 2.5 A with a magnetic trip at 51 A. Breaking capacity is 100 kA Icu at 400/415 V AC. Motor power ranges from 0.37 kW at 230 V to 1.5 kW at 690 V. It's a 3-pole thermal-magnetic device with 1 NO + 1 NC auxiliary contacts.

What standards does the GV2RT07AE11TQ comply with?

It is certified to EN/IEC 60947-2 and EN/IEC 60947-4-1, and is suitable for isolation per IEC 60947-1. Climatic withstand conforms to IACS.

How does the GV2RT07AE11TQ mount in a panel?

It clips onto a 35 mm symmetrical DIN rail or can be screwed to a panel using an adaptor plate. Width is 45 mm, fitting one modular space on the rail.

MPN
GV2RT07AE11TQ