Schneider Electric GV2RT103 — Molded Case Circuit Breakers (MCCB)

Schneider Electric GV2RT103 TeSys Motor Circuit Breaker, 6.3

MPNGV2RT103
Obsolete

Schneider Electric TeSys Deca GV2RT103 motor circuit breaker, 3-pole, 6.3 A rated current, thermal-magnetic trip, spring terminals, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

GV2RT103 — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection Transformer
GV2RT103 — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth78.5 mm
GV2RT103 — Electrical
ParameterValue
[In] rated current6.3 A
Breaking capacity100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2RT103 — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2RT
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1

Product details

Motor Circuit Breaker for Panel Integration

It is certified to both IEC 60947-2 (circuit-breaker standard) and IEC 60947-4-1 (contactor/motor-starter standard), which means it serves as a combined disconnecting and overload-protection device for motor circuits — no separate fuse or overload relay needed upstream for the motor branch. The thermal adjustment range covers 4...6.3 A, letting you dial in the exact full-load current of the motor. The magnetic trip is fixed at 138 A, which clears short-circuit faults without nuisance tripping on motor inrush.

SCCR and Coordination

Rated for 100 kA at 400 V and 50 kA at 500 V, the GV2RT103 sits in the high-interrupting tier of the TeSys Deca family. For panel builders, this means the breaker can be placed ahead of a motor starter without requiring a current-limiting fuse for SCCR compliance up to that fault level — a direct saving in panel space and component count. At 690 V the interrupting rating drops to 3 kA, so coordination studies should verify adequacy at that voltage.

Snaps onto 35 mm symmetrical DIN rail or screws to a panel via an adaptor plate. The spring-cage power terminals accept 1...6 mm² solid or 1.5...4 mm² flexible wire (with or without ferrules), two conductors per terminal. Mounting can be horizontal or vertical; the toggle handle provides manual on/off control and a clear visual position indicator for isolation verification.

Frequently asked questions

What motor power does GV2RT103 protect at 400 V?

At 400/415 V AC 50/60 Hz, the GV2RT103 protects motors up to 2.2 kW (high peak current profile) or 2.5 kW for transformer loads.

What is the breaking capacity of GV2RT103 at 400 V?

The rated ultimate short-circuit breaking capacity (Icu) is 100 kA at 400/415 V AC per IEC 60947-2.

What terminals does GV2RT103 use?

Power circuit connections use spring terminals accepting 1...6 mm² solid or 1.5...4 mm² flexible wire, with or without ferrules, up to two conductors per terminal.

MPN
GV2RT103