GV2RT10AE11TQ — Identification
ParameterValue
Product / component typeMotor circuit breaker
Device applicationMotor protection Transformer
GV2RT10AE11TQ — Mechanical
ParameterValue
Height89 mm
Width45 mm
Depth78.5 mm
GV2RT10AE11TQ — Electrical
ParameterValue
[In] rated current6.3 A
Breaking capacity100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
GV2RT10AE11TQ — Specifications
ParameterValue
Poles description3P
Trip unit technologyThermal-magnetic
Device short nameGV2RT
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1

Product details

It is designed for motor and transformer protection in AC networks, with a breaking capacity of 100 kA Icu at 400/415 V AC 50/60 Hz per IEC 60947-2. The 138 A magnetic trip setting handles inrush without nuisance trips, while the thermal element protects against sustained overloads. Suitability for isolation per IEC 60947-1 means it can serve as a disconnecting means in the motor branch circuit.

The 6.3 A rated current (In) sets the continuous ampacity through the breaker. For motor protection, the unit covers 1.1 kW at 220/230 V and 2.2 kW at 400/415 V AC 50/60 Hz — match this to your motor nameplate FLA. The utilisation category AC-3 per IEC 60947-4-1 confirms it is rated for switching squirrel-cage motors during starting and running. Electrical durability is 100,000 cycles at AC-3, 415 V In — enough for frequent start-stop applications like conveyors or pumps.

The 45 mm width (3-module) fits standard enclosure cutouts. IP20 finger-safe terminals accept up to 2 x 6 mm² solid or 2 x 4 mm² flexible with ferrule. Tightening torque is 1.7 N·m on the screw clamp terminals.

Frequently asked questions

What are the key ratings for this motor circuit breaker?

Rated current 6.3 A, breaking capacity 100 kA Icu at 400/415 V AC, thermal-magnetic trip with 138 A magnetic setting, 1.1 kW motor at 230 V and 2.2 kW at 400 V, AC-3 utilisation category.

What standards does the GV2RT10AE11TQ comply with?

It complies with EN/IEC 60947-2 (circuit-breakers) and EN/IEC 60947-4-1 (contactors and motor-starters), and is suitable for isolation per IEC 60947-1.

Does it include auxiliary contacts?

Yes, it comes with 1 NO + 1 NC front-mounted auxiliary contacts for status signalling.