Schneider Electric GV3D02 — Miniature Circuit Breakers (MCB)

Schneider Electric GV3D02 TeSys Shunt Trip Release, 110-127V

MPNGV3D02
Obsolete

Schneider Electric TeSys GV3D02 shunt trip release, 110-127V AC 50/60Hz control voltage, obsolete status.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV3D02 — Identification
ParameterValue
Product rangeTeSys
Product/component typeShunt trip release
GV3D02 — Ratings
ParameterValue
Rated insulation voltage (Ui)690 V AC IEC 60947-1 600 V AC UL 60947-4-1 600 V AC CSA C22.2 No 60947-4-1
GV3D02 — Protection
ParameterValue
Mechanical durability (cycles)15000 cycles
GV3D02 — Mechanical
ParameterValue
Terminal connection typescrew clamp terminals 1 0.001...0.004 in² (0.75...2.5 mm²)flexible without cable end screw clamp terminals 1 0.002...0.004 in² (1...2.5 mm²)solid screw clamp terminals 2 0.001...0.004 in² (0.75...2.5 mm²)flexible without cable end screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)solid screw clamp terminals 1 0.001...0.004 in² (0.75...2.5 mm²)flexible with cable end screw clamp terminals 2 0.001...0.004 in² (0.75...2.5 mm²)flexible with cable end
Terminal tightening torque1.2 N.m screw clamp terminals

Product details

The Schneider Electric GV3D02 is a shunt trip release (MX) from the TeSys GV3 range, designed to remotely trip a circuit breaker or motor starter via a control signal. It is a service part, sold in a set of 10 units. The release operates with a control circuit voltage of 110 V AC at 50 Hz, 120 V AC at 50/60 Hz, or 127 V AC at 50/60 Hz, with an operating range of 0.8 to 1.1 times the nominal voltage (Un). The threshold tripping voltage is 0.7 to 0.35 Un. Rated insulation voltage (Ui) is 690 V AC per IEC 60947-1, and 600 V AC per UL 60947-4-1 and CSA C22.2 No 60947-4-1, meaning it is suitable for use in panels with those voltage ratings.

The release connects via screw clamp terminals accepting 0.75 to 2.5 mm² flexible or solid wire, with a tightening torque of 1.2 N·m. It draws 7 W inrush (12 VA AC) and holds at 2.5 W (7 VA AC), so the control transformer must be sized to handle the inrush without voltage sag. Mechanical durability is rated at 15,000 cycles, and the operating time is 15 ms per IEC 60947-1. The on-load factor is 100%, meaning it can be continuously energized in the hold state.

Frequently asked questions

What control voltages does the GV3D02 accept?

It accepts 110 V AC at 50 Hz, 120 V AC at 50/60 Hz, and 127 V AC at 50/60 Hz, with an operating range of 0.8 to 1.1 times the nominal voltage.

What compliance documentation is available for the GV3D02?

The part carries IEC 60947-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1 ratings for insulation voltage. Specific RoHS/REACH documentation should be requested with the RFQ, as it is an obsolete service part.