Schneider Electric GV3L656 — Miniature Circuit Breakers (MCB)

Schneider GV3L656 TeSys Deca Motor Circuit Breaker, 65 A

MPNGV3L656
Obsolete

Schneider Electric TeSys Deca GV3L656 motor circuit breaker, 65 A rated current, 3-pole, magnetic trip, rotary handle, IP20, 50 kA Icu at 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV3L656 — Identification
ParameterValue
Product nameTeSys GV3
Product rangeTeSys Deca
Product/component typeMotor circuit breaker
Device applicationMotor protection
GV3L656 — Ratings
ParameterValue
Rated current (In)65 A
Poles configuration3P
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz 50 kA Icu at 400/415 V AC 50/60 Hz 50 kA Icu at 440 V AC 50/60 Hz 12 kA Icu at 500 V AC 50/60 Hz 6 kA Icu at 690 V AC 50/60 Hz
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage (Ui)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz conforming to IEC 60947-2
Utilisation categoryCategory A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1
GV3L656 — Protection
ParameterValue
Trip unit technologyMagnetic
Suitability for isolationYes conforming to IEC 60947-1
Electrical durability (cycles)50000 cycles for AC-3 at 415 V In
Mechanical durability (cycles)50000 cycles
GV3L656 — Mechanical
ParameterValue
Control typeRotary handle
Terminal tightening torque6 N.m - on lugs-ring terminals
Width55 mm
Height132 mm
Depth136 mm
GV3L656 — Environmental
ParameterValue
Operating ambient temperature-20...60 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
GV3L656 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-1:Clause 30.2 IEC/EN 60335-2-40:Annex JJ
GV3L656 — Electrical
ParameterValue
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz 100 % at 400/415 V AC 50/60 Hz 100 % at 440 V AC 50/60 Hz 50 % at 500 V AC 50/60 Hz 50 % at 690 V AC 50/60 Hz

Product details

65 A motor circuit breaker for TeSys Deca panels

The Schneider GV3L656 is a 3-pole motor circuit breaker from the TeSys Deca range, rated 65 A continuous current (In) with a magnetic trip unit that fires at 910 A — roughly 14× In, set to pass motor start inrush without nuisance tripping while clearing a locked-rotor fault. Breaking capacity is 50 kA Icu at 400/415 V AC, 50/60 Hz — enough to handle a bolted fault on a typical 400 V industrial distribution board without the upstream breaker needing to coordinate. At 690 V the Icu drops to 6 kA, which still covers most motor branch circuits at that voltage. Motor power ratings span 30 kW at 400 V to 55 kW at 690 V, so the same breaker body covers a range of motor frame sizes depending on the line voltage.

Mounting and panel fit

Snaps onto 35 mm symmetrical DIN rail or screws direct to the panel backplate with three M4 screws — no adapter plate needed. Dimensions are 136 mm deep × 55 mm wide × 132 mm high, so it occupies about the same footprint as a three-pole contactor in the same family. Connection pitch is 17.5 mm between poles without spreaders, which matches the standard TeSys Deca busbar system for daisy-chaining power across multiple devices on the same DIN rail. IP20 finger-safe terminals — suitable for enclosed panel use; the rotary handle protrudes through the panel door for local on/off/reset without opening the enclosure.

Duty cycle and thermal budget

Rated for uninterrupted duty per IEC 60947-4-1, meaning it carries 65 A continuously without derating in a 40 °C ambient. Power dissipation is 8 W per pole — 24 W total at full load — which factors into the enclosure's internal temperature rise calculation. Electrical endurance is 50,000 cycles in AC-3 at 415 V — that's the motor-switching duty class, not resistive. Mechanical endurance matches at 50,000 cycles, so the contact wear and the mechanism wear are balanced for the same service life. Operating temperature range is -20 to 60 °C, storage -40 to 80 °C. The unit is rated for operation up to 3000 m altitude without derating; above that, the air dielectric and cooling both degrade, so consult the altitude correction table.

Standards and compliance

Certified to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (contactor-starter standard), plus UL 60947-4-1 and CSA C22.2 No 60947-4-1 — so it passes for both IEC and North American panel builds. Also listed for IEC/EN 60335 household-appliance standards for motor protection in HVAC equipment. Suitable for isolation per IEC 60947-1, meaning the open contacts provide a visible-break disconnect that meets the safety isolation requirement for maintenance access. Fire resistance tested to 960 °C glow-wire per IEC 60695-2-11, and climatic withstand per IACS for marine and humid environments.

Frequently asked questions

What is the breaking capacity of the GV3L656 at 400 V?

The GV3L656 has a rated breaking capacity of 50 kA Icu at 400/415 V AC, 50/60 Hz. At 230/240 V it is 100 kA Icu, and at 690 V it is 6 kA Icu.

What motor power does the GV3L656 cover?

Motor power ratings are 30 kW at 400/415 V, 37 kW at 500 V, and 55 kW at 690 V, all at 50/60 Hz.

What compliance documentation does Schneider provide for the GV3L656?

The GV3L656 is certified to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. It also meets IEC/EN 60335 appliance standards and has fire resistance to 960 °C glow-wire per IEC 60695-2-11.