Skip to main content
Schneider Electric GV3P18

Schneider GV3P18 TeSys GV3 Motor Circuit Breaker, 18 A, 3-Po

MPNGV3P18
Obsolete

Schneider Electric TeSys GV3, motor circuit breaker, GV3P18, 3-pole, 18 A, thermal-magnetic, breaking capacity 100 kA at 400/415 V AC.

$60.19Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

GV3P18 key specifications
ParameterValue
Control typeRotary handle
Network typeAC
Product or component typeMotor circuit breaker
Climatic withstandIACS E10
Voltage690 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV IEC 60947-2
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 12 kA Icu 500 V AC 50/60 Hz IEC 60947-2 6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Line rated current18 A
Magnetic tripping current252 A
[Ith] conventional free air thermal current18 A IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 50 % 500 V AC 50/60 Hz IEC 60947-2 50 % 690 V AC 50/60 Hz IEC 60947-2

All specifications

GV3P18 additional specifications
ParameterValue
Motor power7.5 kW 400/415 V AC 50/60 Hz 9 kW 500 V AC 50/60 Hz 15 kW 690 V AC 50/60 Hz
Power dissipation per pole8 W
Network frequency50/60 Hz IEC 60947-2
Poles description3P
Phase failure sensitivityYes IEC 60947-4-1
Rated dutyUninterrupted IEC 60947-4-1
Utilisation categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 IEC 60529
Mounting positionHorizontal Vertical
Operating altitude9842.52 ft (3000 m)
ColorDark grey
Depth5.4 in (136 mm)
Width2.2 in (55 mm)
Height5.2 in (132 mm)
Electrical durability50000 cycles AC-3 415 V In
Mechanical durability50000 cycles
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-1:Clause 30.2 IEC/EN 60335-2-40:Annex JJ
RangeTeSys Deca
CategoryUS10I1122366
Fixing mode35 mm symmetrical DIN rail clipped Panel screwed with 3 x M4 screws)
Fire resistance1760 °F (960 °C) IEC 60695-2-11
Device short nameGV3P
Tightening torque44.3 lbf.in (5 N.m) screw clamp terminal
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Mechanical robustnessShocks 15 Gn for 11 ms contactor open Shocks 30 Gn for 11 ms contactor closed Vibrations 4 Gn, 5...300 Hz
Suitability for isolationYes IEC 60947-1
Ambient air temperature for storage-40...176 °F (-40...80 °C)
Thermal protection adjustment range12...18 A IEC 60947-2
Ambient air temperature for operation-4...140 °F (-20...60 °C)

Product details

The Schneider GV3P18 is a 3-pole motor circuit breaker in the TeSys Deca range, rated 18 A with thermal-magnetic trip and 100 kA breaking capacity at 400/415 V AC. It serves as a combination motor protector: disconnect switch, overload relay, and short-circuit protection in a single DIN-rail or panel-mount unit. Rated for motor loads up to 7.5 kW at 400 V AC or 15 kW at 690 V AC, covering common pump, fan, and compressor applications.

Thermal-magnetic trip unit provides inverse-time overload protection and instantaneous magnetic trip at 252 A for short circuits. Phase failure sensitivity is built in per IEC 60947-4-1. Electrical durability is rated at 50,000 cycles under AC-3 (motor) switching at rated current — sufficient for typical motor start/stop duty in production lines. Overall depth of 136 mm (5.4 in) requires adequate enclosure clearance; panel height of 132 mm and width of 55 mm fit snugly on standard backplates.

Compliance certifications include EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Fire resistance tested to 960 °C (IEC 60695-2-11). IP20 finger-safe terminals with IK09 impact resistance for enclosed mounting.

Frequently asked questions

What compliance documentation does Schneider provide for the GV3P18?

The GV3P18 carries certifications to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Fire resistance per IEC 60695-2-11 and IP20 protection are also certified.

What is the color and depth of the GV3P18?

The GV3P18 is dark grey (Schneider's standard for TeSys Deca). Its depth is 5.4 inches (136 mm), which is important for enclosure clearance when mounting on backplate or DIN rail.

What breaking capacity does the GV3P18 provide?

The GV3P18 offers 100 kA breaking capacity at 230/240 V and 400/415 V AC, 50 kA at 440 V, 12 kA at 500 V, and 6 kA at 690 V per IEC 60947-2.

MPN
GV3P18