Schneider GV4L80S Miniature Breaker
MPNGV4L80S
Obsolete
GV4L80S by SQUARE D
$255.27Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Control type | Rotary handle |
| Range of product | TeSys GV4 |
| Product or component type | Motor circuit breaker |
| Climatic withstand | conforming to IACS E10 |
| Voltage | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 |
| Breaking capacity | 120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Current | 80 A |
| Magnetic tripping current | 480...1120 A |
| [Ith] conventional free air thermal current | 115 A conforming to IEC 60947-4-1 |
| Motor power | 37 kW at 400...415 V AC 50/60 Hz 45 kW at 500 V AC 50/60 Hz 55 kW at 500 V AC 50/60 Hz 22 kW at 400...415 V AC 50/60 Hz 30 kW at 500 V AC 50/60 Hz 37 kW at 660...690 V AC 50/60 Hz 45 kW at 660...690 V AC 50/60 Hz 55 kW at 660...690 V AC 50/60 Hz 30 kW at 400...415 V AC 50/60 Hz 37 kW at 500 V AC 50/60 Hz |
All specifications
| Parameter | Value |
|---|---|
| Power dissipation per pole | 6.1 W |
| Poles description | 3P |
| Rated duty | Continuous conforming to IEC 60947-4-1 |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| Connections - terminals | EverLink BTR screw connectors (top) 1 cable(s) 1.5...70 mm² - solid EverLink BTR screw connectors (top) 1 cable(s) 1.5...50 mm² - flexible EverLink BTR screw connectors (bottom) 1 cable(s) 2.5...95 mm² - solid EverLink BTR screw connectors (bottom) 1 cable(s) 2.5...70 mm² - flexible |
| Pollution degree | 3 |
| Operating altitude | 5000 m |
| Depth | 165 mm |
| Width | 81 mm |
| Color | Grey (RAL 7016) |
| Height | 155 mm |
| Electrical durability | 14000 cycles for AC-3 at 440 V In/2 7000 cycles for AC-3 at 440 V In |
| Mechanical durability | 40000 cycles |
| Standards | EN/IEC 60947-2 EN/IEC 60947-4-1 |
| Range | TeSys Deca |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Device short name | GV4L |
| Tightening torque | 9 N.m for cable 16...95 mm² 5 N.m for cable 1.5...10 mm² |
| Device application | Motor protection |
| Operating position | Any position |
| Trip unit technology | Magnetic Electronic |
| Mechanical robustness | Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27 |
| Maximum operating rate | 25 cyc/h |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Ambient air temperature for storage | -50...85 °C |
| Ambient air temperature for operation | -25...70 °C |
MPN
GV4L80S
