Schneider Electric GV4P02N6

Schneider GV4P02N6 TeSys Deca Motor Circuit Breaker, 2 A

MPNGV4P02N6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4P02N6, 3-pole, 2 A, electronic thermal-magnetic trip, Gray RAL 7016.

$880.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

GV4P02N6 key specifications
ParameterValue
Control typeRotary handle
Range of productTeSys GV4
Product or component typeMotor circuit breaker
Climatic withstandIACS E10
Voltage800 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947
Line rated current2 A
Magnetic tripping current34 A
[Ith] conventional free air thermal current115 A IEC 60947-4-1
Motor power0.25 kW 400...415 V AC 50/60 Hz 0.37 kW 400...415 V AC 50/60 Hz 0.55 kW 400...415 V AC 50/60 Hz 0.75 kW 400...415 V AC 50/60 Hz 0.37 kW 500 V AC 50/60 Hz 0.55 kW 500 V AC 50/60 Hz 0.75 kW 500 V AC 50/60 Hz 1.1 kW 500 V AC 50/60 Hz 0.55 kW 660...690 V AC 50/60 Hz 0.75 kW 660...690 V AC 50/60 Hz 1.1 kW 660...690 V AC 50/60 Hz 1.5 kW 660...690 V AC 50/60 Hz

All specifications

GV4P02N6 additional specifications
ParameterValue
Power dissipation per pole4.6 W
Poles description3P
Phase failure sensitivityYes IEC 60947-4-1
Rated dutyContinuous IEC 60947-4-1
Utilisation categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IK degree of protectionIK07 IEC 62262
IP degree of protectionIP40 IEC 60529
Connection pitch1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Connections - terminalsLugs-ring terminals
Pollution degree3
Operating altitude5000 m
ColorGray RAL 7016)
Depth6.5 in (165 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical durability40000 cycles AC-3 440 V In/2 40000 cycles AC-3 440 V In
Mechanical durability40000 cycles
StandardsCSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2
RangeTeSys Deca
CategoryUS10I1122365
Fire resistance1760 °F (960 °C) IEC 60695-2-11
Device short nameGV4P
Tightening torque79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)
Device applicationMotor protection
Operating positionAny position
Trip unit technologyElectronic Thermal-magnetic
Mechanical robustnessVibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27
Maximum operating rate25 cyc/h
Suitability for isolationYes IEC 60947-1
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)

Product details

The GV4P02N6 is a 2 A, 3-pole motor circuit breaker from the TeSys Deca range, designed for motor protection on three-phase loads. The electronic thermal-magnetic trip unit provides overload and short-circuit protection, with magnetic tripping at 34 A. Phase failure sensitivity is built in per IEC 60947-4-1, eliminating the need for an external phase loss relay on the motor circuit. Breaking capacity reaches 100 kA Icu at 240 V AC (UL) and 65 kA at 240 V under UL, with 50 kA available at 380–415 V AC (IEC). This fault-interruption rating is unusually high for a 2 A frame, making the part suitable for installations with high available short-circuit current. Motor power ratings cover 0.25 kW through 1.5 kW at voltages from 400 V to 690 V AC, 50/60 Hz, in AC-3 utilization category. The AC-3 rating is the relevant load-heavy switching duty for starting and running induction motors.

Dimensions: 155 mm high, 81 mm wide, 165 mm deep. Front panel with rotary handle control. Accepts lug-ring terminals: power wiring up to 95 mm² with a tightening torque of 9 N·m, and control wiring from 1.5 to 10 mm² at 5 N·m. Connection pitch is 27 mm without spreaders, 35 mm with spreaders – factor this into cabinet layout. Operates in any position, altitude up to 5000 m. Pollution degree 3 for industrial environments. Mechanical durability 40,000 cycles; maximum operating rate 25 cycles per hour.

Certified to UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1 and EN/IEC 60947-2. Fire resistance tested to 960°C per IEC 60695-2-11. Suitability for isolation per IEC 60947-1 – the device can be used as a disconnecting means when locked off. Climatic withstand classification IACS covers damp heat. Color is Gray RAL 7016.

Frequently asked questions

What are the compliance standards for GV4P02N6?

It meets UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1 and EN/IEC 60947-2, with fire resistance to 960°C.

What color is GV4P02N6?

The housing is Gray RAL 7016.

What is the depth of GV4P02N6?

Depth is 165 mm (6.5 in).