Skip to main content
Schneider Electric GV4P115N

Schneider GV4P115N TeSys GV4 115A Motor Circuit Breaker

MPNGV4P115N
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4P115N, 3-pole, 115A, electronic/thermal-magnetic trip, gray RAL 7016.

$935.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

GV4P115N key specifications
ParameterValue
Control typeRotary handle
Range of productTeSys GV4
Product or component typeMotor circuit breaker
Climatic withstandIACS E10
Voltage800 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947
Line rated current115 A
Magnetic tripping current1955 A
[Ith] conventional free air thermal current115 A IEC 60947-4-1
Motor power37 kW 400...415 V AC 50/60 Hz 45 kW 400...415 V AC 50/60 Hz 55 kW 400...415 V AC 50/60 Hz 45 kW 500 V AC 50/60 Hz 55 kW 500 V AC 50/60 Hz 75 kW 500 V AC 50/60 Hz 75 kW 660...690 V AC 50/60 Hz 90 kW 660...690 V AC 50/60 Hz 110 kW 660...690 V AC 50/60 Hz

All specifications

GV4P115N additional specifications
ParameterValue
Power dissipation per pole4.6 W
Poles description3P
Phase failure sensitivityYes IEC 60947-4-1
Rated dutyContinuous IEC 60947-4-1
Utilisation categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IK degree of protectionIK07 IEC 62262
IP degree of protectionIP40 IEC 60529
Connections - terminalsEverLink BTR screw connectors top) 1 0.002...0.1 in² (1.5...70 mm²) - solid EverLink BTR screw connectors top) 1 0.002...0.08 in² (1.5...50 mm²) - flexible EverLink BTR screw connectors bottom) 1 0.004...0.1 in² (2.5...95 mm²) - solid EverLink BTR screw connectors bottom) 1 0.004...0.1 in² (2.5...70 mm²) - flexible
Pollution degree3
Operating altitude5000 m
ColorGray RAL 7016)
Depth6.5 in (165 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical durability10000 cycles AC-3 440 V In/2 5000 cycles AC-3 440 V In
Mechanical durability40000 cycles
StandardsCSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2
RangeTeSys Deca
CategoryUS10I1122365
Fire resistance1760 °F (960 °C) IEC 60695-2-11
Device short nameGV4P
Tightening torque79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)
Device applicationMotor protection
Operating positionAny position
Trip unit technologyElectronic Thermal-magnetic
Mechanical robustnessVibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27
Maximum operating rate25 cyc/h
Suitability for isolationYes IEC 60947-1
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)

Product details

The GV4P115N is a 115 A motor circuit breaker from the TeSys Deca range, combining electronic and thermal-magnetic trip technology for AC-3 motor switching duty. Phase-failure detection is built in, and it is approved for isolation per IEC 60947-1.

Fault performance and environmental rating

The 115 A continuous carries a 4.6 W per pole dissipation, so panel thermal rise is predictable. With pollution degree 3 and IP40 enclosure, it holds up in industrial electrical rooms. Altitude rated to 5000 m — no derating for high installations.

Schneider lists this part as current-production. No NRND or phase-out notices are active. For BOM planning, it is a standard line item — no supply risk from discontinuity. Order-to-RFQ lead times apply per quantity.

Physical footprint and termination

Occupies a 6.1 x 3.2 x 6.5 inch volume with any-position mounting. EverLink BTR screw terminals accept 1.5 to 95 mm² conductors. Tightening torque 9 N·m for mains, 5 N·m for control. Mechanical endurance 40,000 cycles; electrical 10,000 at AC-3 rated load.

Frequently asked questions

What is GV4P115N's listed color?

Gray RAL 7016.

What is GV4P115N's listed depth?

6.5 in (165 mm).

What compliance documentation does this brand provide for GV4P115N?

The GV4P115N is certified to CSA C22.2 No 60947-4-1, UL 60947-4-1, and EN/IEC 60947-4-1 and 60947-2.

MPN