Schneider Electric GV4P115N6

Schneider GV4P115N6 TeSys GV4 Motor Circuit Breaker, 115 A

MPNGV4P115N6
Active

Schneider TeSys GV4 series, motor circuit breaker, GV4P115N6, 115 A, 3-pole, electronic thermal-magnetic, 100 kA Icu at 240 V, IP40, Gray RAL 7016.

$990.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

GV4P115N6 key specifications
ParameterValue
Control typeRotary handle
Range of productTeSys GV4
Product or component typeMotor circuit breaker
Climatic withstandIACS E10
Voltage800 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947
Line rated current115 A
Magnetic tripping current1955 A
[Ith] conventional free air thermal current115 A IEC 60947-4-1
Motor power37 kW 400...415 V AC 50/60 Hz 45 kW 400...415 V AC 50/60 Hz 55 kW 400...415 V AC 50/60 Hz 45 kW 500 V AC 50/60 Hz 55 kW 500 V AC 50/60 Hz 75 kW 500 V AC 50/60 Hz 75 kW 660...690 V AC 50/60 Hz 90 kW 660...690 V AC 50/60 Hz 110 kW 660...690 V AC 50/60 Hz

All specifications

GV4P115N6 additional specifications
ParameterValue
Power dissipation per pole4.6 W
Poles description3P
Phase failure sensitivityYes IEC 60947-4-1
Rated dutyContinuous IEC 60947-4-1
Utilisation categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IK degree of protectionIK07 IEC 62262
IP degree of protectionIP40 IEC 60529
Connection pitch1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Connections - terminalsLugs-ring terminals
Pollution degree3
Operating altitude5000 m
ColorGray RAL 7016)
Depth6.5 in (165 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical durability10000 cycles AC-3 440 V In/2 5000 cycles AC-3 440 V In
Mechanical durability40000 cycles
StandardsCSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2
RangeTeSys Deca
CategoryUS10I1122365
Fire resistance1760 °F (960 °C) IEC 60695-2-11
Device short nameGV4P
Tightening torque79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)
Device applicationMotor protection
Operating positionAny position
Trip unit technologyElectronic Thermal-magnetic
Mechanical robustnessVibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27
Maximum operating rate25 cyc/h
Suitability for isolationYes IEC 60947-1
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)

Product details

The GV4P115N6 is a 3-pole motor circuit breaker from Schneider's TeSys GV4 range, rated 115 A line current and built for motor protection under IEC and UL standards. It uses an electronic thermal-magnetic trip unit that combines adjustable overload protection with a fixed magnetic trip of 1955 A, so it clears a bolted fault fast while letting inrush ride through cleanly.

Where it sits in a panel

At 165 mm deep, 81 mm wide, and 155 mm tall, it fits a standard 3-pole breaker footprint in the TeSys Deca frame. The connection pitch is 27 mm without spreaders, 35 mm with, and the lugs accept ring terminals up to 95 mm². Mount it in any orientation, but pollution degree 3 means it's fine for a typical control panel environment — just don't drop it into a washdown zone without an extra enclosure; the IP40 front keeps fingers off terminals but won't stop hose spray.

Electrical performance that matters

The breaking capacity drops with voltage — that's normal, but the numbers here are worth noting because they cover the common industrial bus voltages in one device: 100 kA Icu at 240 V AC (IEC), 50 kA at 415 V, and 35 kA under UL at 480Y/277 V. That last figure is the one most US plants will care about; it exceeds the typical 25 kA fault duty on a 480 V MCC bucket.

Frequently asked questions

What is the color of the GV4P115N6?

The enclosure is finished in gray RAL 7016, per the specification.

What is the depth of the GV4P115N6?

Depth is 165 mm (6.5 in), which is the front-to-back dimension including the rotary handle mechanism.

What compliance standards does the GV4P115N6 meet?

It is certified to CSA C22.2 No 60947-4-1, UL 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2. It also carries an IK07 impact rating and IP40 ingress protection, and passed glow-wire testing at 960 °C per IEC 60695-2-11.

MPN
GV4P115N6