Schneider Electric GV4P80S

Schneider TeSys GV4P80S Motor Circuit Breaker, 80 A, 3-Pole

MPNGV4P80S
Active

Schneider Electric TeSys GV4 series, GV4P80S motor circuit breaker, 3-pole, 80 A rated line current, thermal-magnetic and electronic trip unit, breaking capacity up to 120 kA.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

GV4P80S key specifications
ParameterValue
Control typeRotary handle
Range of productTeSys GV4
Product or component typeMotor circuit breaker
Climatic withstandIACS E10
Voltage800 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 100 kA 208Y/120 V AC 50/60 Hz UL 60947 100 kA 240 V AC 50/60 Hz UL 60947 65 kA 480Y/277 V AC 50/60 Hz UL 60947 10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA 600Y/347 V AC 50/60 Hz UL 60947
Line rated current80 A
Magnetic tripping current1360 A
[Ith] conventional free air thermal current115 A IEC 60947-4-1
Motor power37 kW 400...415 V AC 50/60 Hz 45 kW 500 V AC 50/60 Hz 22 kW 400...415 V AC 50/60 Hz 30 kW 500 V AC 50/60 Hz 37 kW 660...690 V AC 50/60 Hz 45 kW 660...690 V AC 50/60 Hz 55 kW 660...690 V AC 50/60 Hz 30 kW 400...415 V AC 50/60 Hz 37 kW 500 V AC 50/60 Hz

All specifications

GV4P80S additional specifications
ParameterValue
Power dissipation per pole4.6 W
Poles description3P
Phase failure sensitivityYes IEC 60947-4-1
Rated dutyContinuous IEC 60947-4-1
Utilisation categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IK degree of protectionIK07 IEC 62262
IP degree of protectionIP40 IEC 60529
Connections - terminalsEverLink BTR screw connectors top) 1 0.002...0.1 in² (1.5...70 mm²) - solid EverLink BTR screw connectors top) 1 0.002...0.08 in² (1.5...50 mm²) - flexible EverLink BTR screw connectors bottom) 1 0.004...0.1 in² (2.5...95 mm²) - solid EverLink BTR screw connectors bottom) 1 0.004...0.1 in² (2.5...70 mm²) - flexible
Pollution degree3
Operating altitude5000 m
ColorGray RAL 7016)
Depth6.5 in (165 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical durability14000 cycles AC-3 440 V In/2 7000 cycles AC-3 440 V In
Mechanical durability40000 cycles
StandardsCSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2
RangeTeSys Deca
CategoryUS10I1122365
Fire resistance1760 °F (960 °C) IEC 60695-2-11
Device short nameGV4P
Tightening torque79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)
Device applicationMotor protection
Operating positionAny position
Trip unit technologyThermal-magnetic Electronic
Mechanical robustnessVibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27
Maximum operating rate25 cyc/h
Suitability for isolationYes IEC 60947-1
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)

Product details

The Schneider GV4P80S is a 3-pole motor circuit breaker from the TeSys GV4 family, rated at 80 A continuous line current. It combines thermal-magnetic and electronic trip technology in a single unit, sized for motor branch-circuit protection in control panels up to 690 V AC.

Key ratings that decide fit

Breaking capacity is the headline number: 120 kA at 240 V AC, 100 kA at 415 V, and 65 kA at 480Y/277 V AC per UL 60947. For IEC installations, it clears 100 kA at 380–415 V and still holds 10 kA at 690 V. Those figures come from both IEC 60947-2 and UL 60947-4-1 standards, so it's dual-listed for North American and export panels. The trip unit offers thermal-magnetic overload protection plus electronic short-circuit sensing with a magnetic trip threshold of 1360 A. Phase failure sensitivity is built in per IEC 60947-4-1, so a lost phase will not go unnoticed long enough to cook a motor. At 80 A, you are looking at 37 kW on 400–415 V AC (or 45 kW at 500 V). Each pole dissipates 4.6 W.

Rated for continuous duty, pollution degree 3, altitude up to 5000 m, any operating position. IP40 front face, IK07 impact resistance. Connections accept up to 95 mm² copper on the load side—EverLink BTR screw terminals, torqued to 9 N·m.

Frequently asked questions

What is the color of GV4P80S?

Gray RAL 7016 per the manufacturer specification.

What is the depth dimension of GV4P80S?

6.5 inches (165 mm) mounted depth.

What compliance standards does GV4P80S meet?

It is certified to CSA C22.2 No 60947-4-1, UL 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2.

MPN
GV4P80S