Schneider Electric GV4PE02N6

Schneider GV4PE02N6 TeSys GV4 Motor Circuit Breaker, 2 A

MPNGV4PE02N6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4PE02N6, 2 A, 3-pole, thermal-magnetic electronic trip, IP40, Gray RAL 7016.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

GV4PE02N6 key specifications
ParameterValue
Control typeToggle
Range of productTeSys GV4
Product or component typeMotor circuit breaker
Climatic withstandIACS E10
Voltage800 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947
Line rated current2 A
Magnetic tripping current34 A
[Ith] conventional free air thermal current115 A IEC 60947-4-1
Motor power0.25 kW 400...415 V AC 50/60 Hz 0.37 kW 400...415 V AC 50/60 Hz 0.55 kW 400...415 V AC 50/60 Hz 0.75 kW 400...415 V AC 50/60 Hz 0.37 kW 500 V AC 50/60 Hz 0.55 kW 500 V AC 50/60 Hz 0.75 kW 500 V AC 50/60 Hz 1.1 kW 500 V AC 50/60 Hz 0.55 kW 660...690 V AC 50/60 Hz 0.75 kW 660...690 V AC 50/60 Hz 1.1 kW 660...690 V AC 50/60 Hz 1.5 kW 660...690 V AC 50/60 Hz

All specifications

GV4PE02N6 additional specifications
ParameterValue
Power dissipation per pole4.6 W
Poles description3P
Phase failure sensitivityYes IEC 60947-4-1
Rated dutyContinuous IEC 60947-4-1
Utilisation categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IK degree of protectionIK07 IEC 62262
IP degree of protectionIP40 IEC 60529
Connection pitch1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Connections - terminalsLugs-ring terminals
Pollution degree3
Operating altitude5000 m
ColorGray RAL 7016)
Depth4.6 in (116 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical durability40000 cycles AC-3 440 V In/2 40000 cycles AC-3 440 V In
Mechanical durability40000 cycles
StandardsCSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2
RangeTeSys Deca
CategoryUS10I1122365
Fire resistance1760 °F (960 °C) IEC 60695-2-11
Device short nameGV4PE
Tightening torque79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)
Device applicationMotor protection
Operating positionAny position
Trip unit technologyThermal-magnetic Electronic
Mechanical robustnessVibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27
Maximum operating rate25 cyc/h
Suitability for isolationYes IEC 60947-1
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)

Product details

Motor circuit breaker for heavy industrial protection

The Schneider Electric GV4PE02N6 is a 3-pole motor circuit breaker in the TeSys Deca range, rated 2 A continuous current for motor protection per EN/IEC 60947-4-1 and UL 60947-4-1, with CSA C22.2 No 60947-4-1 compliance. Trip technology is thermal-magnetic electronic, including phase failure sensitivity per IEC 60947-4-1 and magnetic tripping at 34 A.

Breaking capacity and fault handling

Breaking capacity reaches 100 kA Icu at 220–240 V AC under IEC 60947-2 and 65 kA at 240 V AC under UL 60947, providing high SCCR for industrial motor circuits. At 380–415 V AC, Icu is 50 kA; at 660–690 V AC, 8 kA. Mechanical and electrical durability rated at 40,000 cycles in AC-3 duty at 440 V, with a maximum operating rate of 25 cycles per hour.

Mounting and environmental ratings

IP40 enclosure with IK07 impact resistance, pollution degree 3, and operating altitude up to 5000 m. Line and load terminals accept 16–95 mm² lugs or ring terminals; tightening torque 79.7 lbf·in (9 N·m). Fire resistance tested to 1760 °F (960 °C) per IEC 60695-2-11.

Frequently asked questions

What is GV4PE02N6's listed color?

Gray RAL 7016.

What is GV4PE02N6's listed depth?

4.6 in (116 mm).

What compliance documentation does this brand provide for GV4PE02N6?

It meets CSA C22.2 No 60947-4-1, UL 60947-4-1, and EN/IEC 60947-4-1 and EN/IEC 60947-2. Fire resistance is tested to 1760 °F (960 °C) per IEC 60695-2-11.

MPN
GV4PE02N6