Skip to main content
Schneider Electric GV4PEM02N6

Schneider GV4PEM02N6 Motor Circuit Breaker, 2A, 3P, TeSys De

MPNGV4PEM02N6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4PEM02N6, 3-pole, line rated 2 A, electronic thermal-magnetic trip, IP40, gray RAL 7016.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

GV4PEM02N6 key specifications
ParameterValue
Control typeToggle
Range of productTeSys GV4
Product or component typeMotor circuit breaker
Climatic withstandIACS E10
Voltage800 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947
Line rated current2 A
Magnetic tripping current34 A
[Ith] conventional free air thermal current115 A IEC 60947-4-1
Motor power0.25 kW 400...415 V AC 50/60 Hz 0.37 kW 400...415 V AC 50/60 Hz 0.55 kW 400...415 V AC 50/60 Hz 0.75 kW 400...415 V AC 50/60 Hz 0.37 kW 500 V AC 50/60 Hz 0.55 kW 500 V AC 50/60 Hz 0.75 kW 500 V AC 50/60 Hz 1.1 kW 500 V AC 50/60 Hz 0.55 kW 660...690 V AC 50/60 Hz 0.75 kW 660...690 V AC 50/60 Hz 1.1 kW 660...690 V AC 50/60 Hz 1.5 kW 660...690 V AC 50/60 Hz

All specifications

GV4PEM02N6 additional specifications
ParameterValue
Power dissipation per pole4.6 W
Poles description3P
Phase failure sensitivityYes IEC 60947-4-1
Rated dutyContinuous IEC 60947-4-1
Utilisation categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IK degree of protectionIK07 IEC 62262
IP degree of protectionIP40 IEC 60529
Connection pitch1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Connections - terminalsLugs-ring terminals
Pollution degree3
Operating altitude5000 m
ColorGray RAL 7016)
Depth4.6 in (116 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical durability40000 cycles AC-3 440 V In/2 40000 cycles AC-3 440 V In
Mechanical durability40000 cycles
StandardsCSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2
RangeTeSys Deca
CategoryUS10I1122365
Fire resistance1760 °F (960 °C) IEC 60695-2-11
Device short nameGV4PEM
Tightening torque79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)
Device applicationMotor protection
Operating positionAny position
Trip unit technologyElectronic Thermal-magnetic
Mechanical robustnessVibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27
Maximum operating rate25 cyc/h
Suitability for isolationYes IEC 60947-1
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)

Product details

Motor protection for the TeSys Deca frame

The GV4PEM02N6 is a 3-pole motor circuit breaker on the TeSys Deca frame, line rated for 2 A continuous. The electronic thermal-magnetic trip unit combines adjustable overload protection with a fixed magnetic pickup of 34 A for short-circuit clearance. Rated for AC-3 duty (motors), it delivers 100 kA Icu breaking capacity at 240 V AC and 50 kA at 415 V AC per IEC 60947-2. For UL 60947 listings, 65 kA at 240 V and 35 kA at 480Y/277 V. Phase failure sensitivity is included; the breaker isolates the motor on single-phasing conditions. Continuous duty rated per IEC 60947-4-1.

Physical integration and environmental ratings

Enclosure is IP40 with IK07 mechanical impact protection, gray RAL 7016. Depth 4.6 in (116 mm), width 3.2 in (81 mm), height 6.1 in (155 mm). Pollution degree 3, operating altitude up to 5000 m. Connection pitch is 1.06 in (27 mm) without spreaders, 1.4 in (35 mm) with. Terminals accept lugs or ring terminals; tightening torque for the power circuit is 79.7 lbf·in (9 N·m) for 16–95 mm² conductors, 44.3 lbf·in (5 N·m) for 1.5–10 mm². Mechanical and electrical durability: 40,000 cycles for both (AC-3 at 440 V In). Maximum operating rate 25 cycles/h. Vibration and shock tested per IEC 60068-2-6 and -2-27.

The GV4PEM02N6 is listed under UL 60947-4-1 and CSA C22.2 No 60947-4-1, plus EN/IEC 60947-4-1 and EN/IEC 60947-2. Fire resistance rated to 1760 °F (960 °C) per IEC 60695-2-11. This is a current-production part (lifecycle stage: current). Submit an inquiry for lead time and pricing.

Frequently asked questions

What color is the GV4PEM02N6?

Gray RAL 7016.

What is the depth of the GV4PEM02N6?

4.6 in (116 mm).

What compliance standards does the GV4PEM02N6 meet?

UL 60947-4-1, CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2. Fire resistance tested to 960 °C (IEC 60695-2-11).

MPN