Skip to main content
Schneider Electric GV4PEM03N6

Schneider GV4PEM03N6 TeSys GV4 Motor Circuit Breaker, 3.5 A,

MPNGV4PEM03N6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4PEM03N6, 3-pole, 3.5 A line rated current, electronic thermal-magnetic trip, AC-3 duty, breaking capacity 100 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

GV4PEM03N6 key specifications
ParameterValue
Control typeToggle
Range of productTeSys GV4
Product or component typeMotor circuit breaker
Climatic withstandIACS E10
Voltage800 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947
Line rated current3.5 A
Magnetic tripping current59 A
[Ith] conventional free air thermal current115 A IEC 60947-4-1
Motor power0.55 kW 400...415 V AC 50/60 Hz 0.75 kW 400...415 V AC 50/60 Hz 0.75 kW 500 V AC 50/60 Hz 1.1 kW 500 V AC 50/60 Hz 1.1 kW 660...690 V AC 50/60 Hz 1.5 kW 660...690 V AC 50/60 Hz 1.5 kW 500 V AC 50/60 Hz 2.2 kW 660...690 V AC 50/60 Hz 1.1 kW 400...415 V AC 50/60 Hz 1.5 kW 400...415 V AC 50/60 Hz

All specifications

GV4PEM03N6 additional specifications
ParameterValue
Power dissipation per pole4.6 W
Poles description3P
Phase failure sensitivityYes IEC 60947-4-1
Rated dutyContinuous IEC 60947-4-1
Utilisation categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IK degree of protectionIK07 IEC 62262
IP degree of protectionIP40 IEC 60529
Connection pitch1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Connections - terminalsLugs-ring terminals
Pollution degree3
Operating altitude5000 m
ColorGray RAL 7016)
Depth4.6 in (116 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical durability40000 cycles AC-3 440 V In/2 40000 cycles AC-3 440 V In
Mechanical durability40000 cycles
StandardsCSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2
RangeTeSys Deca
CategoryUS10I1122365
Fire resistance1760 °F (960 °C) IEC 60695-2-11
Device short nameGV4PEM
Tightening torque79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)
Device applicationMotor protection
Operating positionAny position
Trip unit technologyElectronic Thermal-magnetic
Mechanical robustnessVibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27
Maximum operating rate25 cyc/h
Suitability for isolationYes IEC 60947-1
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)

Product details

TeSys GV4 motor circuit breaker GV4PEM03N6 is a 3-pole device rated 3.5 A line current, designed for motor protection under AC-3 utilization (IEC 60947-4-1). Its electronic thermal-magnetic trip unit provides phase failure sensitivity and adjustable magnetic tripping at 59 A.

Dimensions 81 mm wide x 155 mm high x 116 mm deep (3.2 x 6.1 x 4.6 in). Connects via lug-ring terminals; tightening torque 5 N·m for 1.5–10 mm² and 9 N·m for 16–95 mm². Connection pitch is 27 mm (1.06 in) without spreaders, 35 mm (1.4 in) with. Pollution degree 3 rated, IP40 front panel protection, IK07 impact resistance. Operating altitude to 5000 m, any mounting position allowed. Climatic withstand per IACS.

Operational Constraints & Electrical Durability

Maximum operating rate 25 cyc/h, electrical durability 40000 cycles at AC-3 440 V, mechanical durability 40000 cycles, and power dissipation per pole 4.6 W. Rated for continuous duty IEC 60947-4-1 and suitability for isolation IEC 60947-1.

Frequently asked questions

What compliance certifications does GV4PEM03N6 hold?

It is certified to CSA C22.2 No 60947-4-1, UL 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2.

What is the depth dimension of this motor circuit breaker?

The depth is 4.6 in (116 mm).

What is the listed color for GV4PEM03N6?

The housing color is Gray RAL 7016.

MPN
GV4PEM03N6