GV4PEM07N6 key specifications
ParameterValue
Control typeToggle
Range of productTeSys GV4
Product or component typeMotor circuit breaker
Climatic withstandIACS E10
Voltage800 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947
Line rated current7 A
Magnetic tripping current119 A
[Ith] conventional free air thermal current115 A IEC 60947-4-1
Motor power1.5 kW 400...415 V AC 50/60 Hz 2.2 kW 400...415 V AC 50/60 Hz 2.5 kW 400...415 V AC 50/60 Hz 3 kW 400...415 V AC 50/60 Hz 2.2 kW 500 V AC 50/60 Hz 2.5 kW 500 V AC 50/60 Hz 3 kW 500 V AC 50/60 Hz 4 kW 500 V AC 50/60 Hz 3 kW 660...690 V AC 50/60 Hz 4 kW 660...690 V AC 50/60 Hz 5.5 kW 660...690 V AC 50/60 Hz 7.5 kW 660...690 V AC 50/60 Hz

All specifications

GV4PEM07N6 additional specifications
ParameterValue
Power dissipation per pole4.6 W
Poles description3P
Phase failure sensitivityYes IEC 60947-4-1
Rated dutyContinuous IEC 60947-4-1
Utilisation categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IK degree of protectionIK07 IEC 62262
IP degree of protectionIP40 IEC 60529
Connection pitch1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Connections - terminalsLugs-ring terminals
Pollution degree3
Operating altitude5000 m
ColorGray RAL 7016)
Depth4.6 in (116 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical durability40000 cycles AC-3 440 V In/2 40000 cycles AC-3 440 V In
Mechanical durability40000 cycles
StandardsCSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2
RangeTeSys Deca
CategoryUS10I1122365
Fire resistance1760 °F (960 °C) IEC 60695-2-11
Device short nameGV4PEM
Tightening torque79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)
Device applicationMotor protection
Operating positionAny position
Trip unit technologyThermal-magnetic Electronic
Mechanical robustnessVibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27
Maximum operating rate25 cyc/h
Suitability for isolationYes IEC 60947-1
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)

Product details

The Schneider GV4PEM07N6 is a 7 A, 3-pole motor circuit breaker from the TeSys Deca range, rated for motor protection with a 100 kA breaking capacity at 240 V AC — that SCCR headroom covers most 240 V panels without a downstream fuse. Magnetic tripping current is set at 119 A, so on a short-circuit above that threshold it opens fast, while the thermal-magnetic element handles overload profiles per IEC 60947-4-1. The motor power kW table covers from 1.5 kW up to 7.5 kW depending on voltage (400–690 V AC), which gives flexibility across common European and North American line voltages. Electrical durability is rated at 40,000 cycles at AC-3 440 V, so it's built for moderate-duty motor starts.

Dimensions are 6.1 in high, 3.2 in wide, 4.6 in deep — fits a compact panel footprint. Connection pitch is 27 mm without spreaders, 35 mm with; terminals accept lugs or ring terminals up to 95 mm². Operates in any position, IP40 front, IK07 impact resistance. For panel heat, each pole dissipates 4.6 W at rated current.

Frequently asked questions

What are the key electrical ratings?

Rated current 7 A, 3-pole, magnetic trip at 119 A, breaking capacity up to 100 kA at 240 V AC. Thermal-magnetic trip, category A, AC-3 duty. Phase failure sensitive.

What compliance standards does it meet?

Listed to UL 60947-4-1, CSA C22.2 No 60947-4-1, and EN/IEC 60947-4-1. Also meets EN/IEC 60947-2 for circuit-breaker function.

What color is the enclosure?

Gray RAL 7016.

What is the physical depth?

4.6 in (116 mm).

MPN
GV4PEM07N6