Specifications

GV4PEM115N6 key specifications
ParameterValue
Control typeToggle
Range of productTeSys GV4
Product or component typeMotor circuit breaker
Climatic withstandIACS E10
Voltage800 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 65 kA 208Y/120 V AC 50/60 Hz UL 60947 65 kA 240 V AC 50/60 Hz UL 60947 35 kA 480Y/277 V AC 50/60 Hz UL 60947 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA 600Y/347 V AC 50/60 Hz UL 60947
Line rated current115 A
Magnetic tripping current1955 A
[Ith] conventional free air thermal current115 A IEC 60947-4-1
Motor power37 kW 400...415 V AC 50/60 Hz 45 kW 400...415 V AC 50/60 Hz 55 kW 400...415 V AC 50/60 Hz 45 kW 500 V AC 50/60 Hz 55 kW 500 V AC 50/60 Hz 75 kW 500 V AC 50/60 Hz 75 kW 660...690 V AC 50/60 Hz 90 kW 660...690 V AC 50/60 Hz 110 kW 660...690 V AC 50/60 Hz

All specifications

GV4PEM115N6 additional specifications
ParameterValue
Power dissipation per pole4.6 W
Poles description3P
Phase failure sensitivityYes IEC 60947-4-1
Rated dutyContinuous IEC 60947-4-1
Utilisation categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IK degree of protectionIK07 IEC 62262
IP degree of protectionIP40 IEC 60529
Connection pitch1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Connections - terminalsLugs-ring terminals
Pollution degree3
Operating altitude5000 m
ColorGray RAL 7016)
Depth4.6 in (116 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical durability10000 cycles AC-3 440 V In/2 5000 cycles AC-3 440 V In
Mechanical durability40000 cycles
StandardsCSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2
RangeTeSys Deca
CategoryUS10I1122365
Fire resistance1760 °F (960 °C) IEC 60695-2-11
Device short nameGV4PEM
Tightening torque79.7 lbf.in (9 N.m) 0.02...0.1 in² (16...95 mm²) 44.3 lbf.in (5 N.m) 0.002...0.02 in² (1.5...10 mm²)
Device applicationMotor protection
Operating positionAny position
Trip unit technologyElectronic Thermal-magnetic
Mechanical robustnessVibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27
Maximum operating rate25 cyc/h
Suitability for isolationYes IEC 60947-1
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)

Product details

The GV4PEM115N6 from Schneider's TeSys Deca line is a 115 A, 3-pole motor circuit breaker with electronic thermal-magnetic trip, built for AC-3 motor duty. The continuous duty rating matches IEC 60947-4-1, meaning it can carry the motor load indefinitely when properly sized.

Dimensions are 6.1 x 3.2 x 4.6 in (155 x 81 x 116 mm), with connection pitch of 1.06 in (27 mm) without spreaders or 1.4 in (35 mm) with. Terminals accept lugs or ring terminals up to 95 mm² on the line side and 10 mm² for control wiring. Tightening torque is 9 N·m for power connections, 5 N·m for control.

Electrical durability is 10,000 cycles at AC-3 440 V at In/2, and 5,000 at full In. Mechanical durability is 40,000 cycles. Maximum operating rate is 25 cycles per hour. Power dissipation is 4.6 W per pole, so thermal management in dense panels is straightforward.

Frequently asked questions

What are the key electrical ratings of this motor circuit breaker?

It is rated 115 A line current, 3-pole, with breaking capacity up to 100 kA at 240 V AC (IEC) and 65 kA at 240 V (UL). It is suitable for AC-3 motor duty per IEC 60947-4-1.

What compliance standards does GV4PEM115N6 meet?

It complies with CSA C22.2 No 60947-4-1, UL 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2.

What is the color and depth of this device?

Color is Gray RAL 7016; depth is 4.6 in (116 mm).

MPN